. 2020 Jul;75(7):563.e1-563.e9.
doi: 10.1016/j.crad.2020.03.034. Epub 2020 Apr 22.

Perianal fistula mapping at 3 T: volumetric versus conventional MRI sequences

Affiliations

Perianal fistula mapping at 3 T: volumetric versus conventional MRI sequences

M N Cerit et al. Clin Radiol. 2020 Jul.

Abstract

Aim: To evaluate volumetric contrast-enhanced three-dimensional T1-weighted (CE 3D T1) turbo spin-echo (TSE) with variable flip angle (SPACE), CE 3D T1 volumetric interpolated breath-hold examination (VIBE) sequences with conventional CE-two-dimensional (2D)-T1 and 2D-T2-weighted imaging (WI) sequences in assessing perianal fistulas.

Methods and materials: Twenty-three patients with perianal fistula were included in this prospective study and underwent pelvic magnetic resonance imaging (MRI) at 3 T including fat-supressed CE 3D T1 SPACE, CE 3D T1 VIBE, axial and coronal 2D-T1WI together with 2D-T2WI sequences in the axial and coronal planes. Acquisition times were recorded. Performance of each sequence was evaluated in terms of image quality, presence of artefacts, lesion conspicuity, fistula type, presence of abscess, visibility of internal orifice, and number of internal orifices. Results were compared with post-surgical findings defined as the reference standard.

Results: Both CE 3D T1 VIBE and CE 3D T1 SPACE were the best sequences to determine fistula type and in terms of image quality, artefacts, and determining locations of internal orifices. The number of internal orifices was detected correctly in 23 (100%) patients for CE 3D T1 SPACE and CE 3D T1 VIBE sequences, in 17 (73.9%) patients on CE-T1WI, and in seven (30.4%) patients on 2D-T2WI. Lesion conspicuity was higher for CE 3D T1 SPACE and CE 3D T1 VIBE sequences compared to the 2D sequences (p<0.05). The overall acquisition time for each 3D sequence was shorter compared to the 2D sequences combined.

Conclusion: CE 3D T1 SPACE and CE 3D T1 VIBE sequences may outperform conventional 2D sequences in the evaluation of perianal fistulas in terms of visibility and number of internal orifices with a shorter scanning time.