Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 May 1;30(3):218–228.
doi: 10.1123/ijsnem.2019-0308. Epub 2020 Apr 25.

Sweat Characteristics of Cramp-Prone and Cramp-Resistant Athletes

Affiliations

Sweat Characteristics of Cramp-Prone and Cramp-Resistant Athletes

Kevin C Miller et al. Int J Sport Nutr Exerc Metab. .

Abstract

Exercise-associated muscle cramps (EAMCs) are thought to be caused by dehydration and/or electrolyte losses. In this multicenter, cross-sectional study, the authors determined whether sweat rates (SRs), sweat electrolyte concentrations, or sweat electrolyte content differed in athletes with (i.e., crampers) and without (i.e., noncrampers) a history of EAMCs and whether these variables could predict EAMC-prone athletes. Male and female collegiate athletes (N = 350) from 11 sports with (n = 245) and without (n = 105) a self-reported history of EAMCs completed a typical exercise or conditioning session. SRs, calculated from body mass, and posterior forearm sweat were analyzed for sweat sodium concentration ([Na+]sw), sweat potassium concentration ([K+]sw), and sweat chloride concentration ([Cl-]sw). The authors used SRs and sweat electrolyte concentrations to calculate sweat electrolyte content lost. Within each gender, no differences in SRs (204 males, p = .92; 146 females, p = .24); [Na+]sw (191 males, p = .55; 126 females, p = .55); Na+sw content (191 males, p = .59; 126 females, p = .20); [K+]sw (192 males, p = .57; 126 females, p = .87); K+sw content (192 males, p = .49; 126 females, p = .03); [Cl-]sw (192 males, p = .94; 77 females, p = .57); and Cl-sw content (192 males, p = .55; 77 females, p = .34) occurred between crampers and noncrampers. Receiver operating characteristic curve analysis revealed that sweat electrolyte content and SRs were predictive of EAMC-prone athletes in American football (area under curve = 0.65-0.72, p ≤ .005), but not in any other sport. EAMCs may not be solely caused by fluid or electrolyte losses in most athletes. Fluid and electrolyte replacement may help American footballers. Clinicians should individualize fluid and electrolyte replacement and understand different etiologies for EAMCs.

Keywords: chloride; dehydration; electrolytes; potassium; sodium.

PubMed Disclaimer

LinkOut - more resources