Approximations to the Voice of a Cochlear Implant: Explorations With Single-Sided Deaf Listeners

Affiliations

Approximations to the Voice of a Cochlear Implant: Explorations With Single-Sided Deaf Listeners

Michael F Dorman et al. Trends Hear. 2020 Jan-Dec.

Erratum in

Abstract

Fourteen single-sided deaf listeners fit with an MED-EL cochlear implant (CI) judged the similarity of clean signals presented to their CI and modified signals presented to their normal-hearing ear. The signals to the normal-hearing ear were created by (a) filtering, (b) spectral smearing, (c) changing overall fundamental frequency (F0), (d) F0 contour flattening, (e) changing formant frequencies, (f) altering resonances and ring times to create a metallic sound quality, (g) using a noise vocoder, or (h) using a sine vocoder. The operations could be used singly or in any combination. On a scale of 1 to 10 where 10 was a complete match to the sound of the CI, the mean match score was 8.8. Over half of the matches were 9.0 or higher. The most common alterations to a clean signal were band-pass or low-pass filtering, spectral peak smearing, and F0 contour flattening. On average, 3.4 operations were used to create a match. Upshifts in formant frequencies were implemented most often for electrode insertion angles less than approximately 500°. A relatively small set of operations can produce signals that approximate the sound of the MED-EL CI. There are large individual differences in the combination of operations needed. The sound files in Supplemental Material approximate the sound of the MED-EL CI for patients fit with 28-mm electrode arrays.

Keywords: cochlear implant; single-sided deafness; sound quality.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Estimated Spiral Ganglion Frequency as Function of Electrode Number. Open circles = individual patients. Filled squares = CF of filter. The mean and standard deviation are superimposed on the individual data points at each electrode location.
Figure 2.
Figure 2.
Ratings for Similarity of Simulation to CI Sound Quality.
Figure 3.
Figure 3.
Operations Needed to Make Matches to CI Sound Quality.

References

    1. Arndt S., Aschendorff A., Laszig R., Beck R., Schild C., Kroeger S., Ihorst G., Wesarg T.(2011). Comparison of pseudo-binaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus. Otology and Neurotology, 32(1), 39–47. 10.1097/MAO.0b013e3181fcf271 - DOI - PubMed
    1. Baer T., Moore B.(1993). Effects of spectral smearing on the intelligibility of sentences in noise. Journal of the Acoustical Society of America, 94(3), 1229–1241. 10.1121/1.408176 - DOI - PubMed
    1. Blamey P., Artieres F., Başkent D., Bergeron F., Beynon A., Burke E., Dillier N., Dowell R., Fraysse B., Gallégo S., Govaerts P. J., Green K., Huber A. M., Kleine-Punte A, Maat B., Marx M., Mawman D., Mosnier I., O’Connor A. F., . . Lazard D. S.(2013). Factors affecting auditory performance of post-linguistically deaf adults using cochlear implants: An update with 2251 patients. Audiology and Neurotology, 18(1), 36–47. 10.1159/000343189 - DOI - PubMed
    1. Boëx C., Baud L., Cosendai G., Sigrist A., Kós M-I., Pelizzone M.(2006). Acoustic to electric pitch comparisons in cochlear implant subjects with residual hearing, Journal of the Association for Research in Otolaryngology, 7(2), 110–124. 10.1007/s10162-005-0027-2 - DOI - PMC - PubMed
    1. Dorman M. F., Loizou P., Rainey D.(1997). Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. Journal of the Acoustical Society of America, 102(5), 2993–2996. 10.1121/1.420354 - DOI - PubMed

Publication types

LinkOut - more resources