Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jul;412(17):4183-4194.
doi: 10.1007/s00216-020-02657-x. Epub 2020 May 2.

Development of a thin-film solid-phase microextraction (TF-SPME) method coupled to liquid chromatography and tandem mass spectrometry for high-throughput determination of steroid hormones in white sucker fish plasma

Affiliations

Development of a thin-film solid-phase microextraction (TF-SPME) method coupled to liquid chromatography and tandem mass spectrometry for high-throughput determination of steroid hormones in white sucker fish plasma

Małgorzata Maciążek-Jurczyk et al. Anal Bioanal Chem. 2020 Jul.

Abstract

Steroid hormones (SH) play a number of important physiological roles in vertebrates including fish. Changes in SH concentration significantly affect reproduction, differentiation, development, or metabolism. The objective of this study was to develop an in vitro high-throughput thin-film solid-phase microextraction (TF-SPME)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for targeted analysis of endogenous SH (cortisol, testosterone, progesterone, estrone (E1), 17β-estradiol (E2), and 17α-ethinylestradiol (EE2)) in wild white sucker fish plasma where the concentrations of the analytes are substantially low. A simple TF-SPME method enabled the simultaneous determination of free and total SH concentrations. The use of biocompatible coating allowed direct extraction of these hormones from complex biological samples without prior preparation. The carryover was less than 3%, thereby ensuring reusability of the devices and reproducibility. The results showed that TF-SPME was suitable for the analysis of compounds in the polarity range between 1.28 and 4.31 such as SH at different physicochemical properties. The proposed method was validated according to bioanalytical method validation guidelines. The limit of detection (LOD) and limit of quantification(LOQ) for cortisol, testosterone, progesterone, E1, E2, and EE2 were from 0.006 to 0.150 ng/mL and from 0.020 to 0.500 ng/mL, respectively. The recovery for the method was about 85%, and the accuracy and precision of the method for cortisol, testosterone, and progesterone were ≤ 6.0% and ≤ 11.2%, respectively, whereas those for E1, E2, and EE2 were ≤ 15.0% and ≤ 10.2%, respectively. On the basis of this study, TF-SPME demonstrated several important advantages such as simplicity, sensitivity, and robustness under laboratory conditions. Graphical abstract.

Keywords: Fish steroid hormones; LC–MS/MS; Thin-film coated blades; Thin-film solid-phase microextraction.

PubMed Disclaimer

MeSH terms

LinkOut - more resources