Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code
- PMID: 32372883
- PMCID: PMC7191211
- DOI: 10.1016/j.rpor.2020.03.022
Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code
Abstract
Implementation of a modern treatment technique, such as IMRT, has been improved. In line with that, Monte Carlo (MC) simulations of this technique require the ability of complex beam configurations modelling with respect to the patient. The source 20 DOSXYZnrc with the dynamic and step and shoot technique can be used to simulate the modality. However, they have a different process to obtain the dose distribution in a certain phantom. This study aimed to compare the simulation efficiency and isodose dose distribution in a water phantom from various beam angles and multileaf collimator (MLC) positions in an IMRT plan using source 20. The 30 × 30 × 30 cm3 phantom was irradiated by Varian Clinac iX10MV photon beam with various field sizes from 2 × 2 to 6 × 6 cm2 using some beam angles 5°, 30°, 90°, 180°, and 300° and maintaining the source to surface distance (SSD) of 100 cm. The field-by-field and five-field methods were used to obtain the 3-dimensional (3D) dose distribution. The dose distribution of these methods was compared using the gamma index, DVH analysis, and simulation efficiency. Higher efficiency is better because it implies that it takes less time to reach a given uncertainty. The implementation of source 20 has been validated, with similar results, with validated source in DOSXYZnrc. The identical 3D-dimensions dose distributions using source 20 for dynamic and step and shoot were observed. Two simulations used the same number of histories with the statistical uncertainty of less than 3%. The step and shoot technique was more efficient than the dynamic simulation.
© 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
Figures







Similar articles
-
EGSnrc application for IMRT planning.Rep Pract Oncol Radiother. 2020 Mar-Apr;25(2):217-226. doi: 10.1016/j.rpor.2020.01.004. Epub 2020 Jan 22. Rep Pract Oncol Radiother. 2020. PMID: 32194347 Free PMC article.
-
Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam.Z Med Phys. 2011 May;21(2):124-34. doi: 10.1016/j.zemedi.2010.10.010. Epub 2011 Jan 15. Z Med Phys. 2011. PMID: 21239148
-
Monte Carlo calculation of helical tomotherapy dose delivery.Med Phys. 2008 Aug;35(8):3491-500. doi: 10.1118/1.2948409. Med Phys. 2008. PMID: 18777909
-
Monte Carlo simulation of a dynamic MLC based on a multiple source model.Phys Med Biol. 2001 Dec;46(12):3241-57. doi: 10.1088/0031-9155/46/12/312. Phys Med Biol. 2001. PMID: 11768503
-
Monte Carlo simulation of a dynamic MLC: implementation and applications.Z Med Phys. 2001;11(3):163-70. doi: 10.1016/s0939-3889(15)70508-8. Z Med Phys. 2001. PMID: 11668813
References
-
- Ma C-M, Pawlicki T, Jiang SB. Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. Phys Med Biol. 2000;45(9):2483–2495. - PubMed
-
- Quino LAV, Hernandez CIH, Papanikolaou N. A Monte Carlo model for independent dose verification in IMRT and VMAT for the Varian Novalis TX with high definition MLC. Int J Cancer Ther Oncol. 2015;3(3):1–7.
-
- Jones AO, Das IJ, Jones F.L. A Monte Carlo study of IMRT beamlets in inhomogeneous media. Med. Phys. 2003;30(3):296–300. - PubMed
-
- Rice RK, Hansen JL, Svensson GK, Siddon R.L. Measurements of dose distributions in small beams of 6 MV x-rays. Phys Med Biol. 1987;32:1087–1099. - PubMed
LinkOut - more resources
Full Text Sources