Abstract
Background: Photographic diabetic retinopathy screening requires labour-intensive grading of retinal images by humans. Automated retinal image analysis software (ARIAS) could provide an alternative to human grading. We compare the performance of an ARIAS using true-colour, wide-field confocal scanning images and standard fundus images in the English National Diabetic Eye Screening Programme (NDESP) against human grading.
Methods: Cross-sectional study with consecutive recruitment of patients attending annual diabetic eye screening. Imaging with mydriasis was performed (two-field protocol) with the EIDON platform (CenterVue, Padua, Italy) and standard NDESP cameras. Human grading was carried out according to NDESP protocol. Images were processed by EyeArt V.2.1.0 (Eyenuk Inc, Woodland Hills, California). The reference standard for analysis was the human grade of standard NDESP images.
Results: We included 1257 patients. Sensitivity estimates for retinopathy grades were: EIDON images; 92.27% (95% CI: 88.43% to 94.69%) for any retinopathy, 99% (95% CI: 95.35% to 100%) for vision-threatening retinopathy and 100% (95% CI: 61% to 100%) for proliferative retinopathy. For NDESP images: 92.26% (95% CI: 88.37% to 94.69%) for any retinopathy, 100% (95% CI: 99.53% to 100%) for vision-threatening retinopathy and 100% (95% CI: 61% to 100%) for proliferative retinopathy. One case of vision-threatening retinopathy (R1M1) was missed by the EyeArt when analysing the EIDON images, but identified by the human graders. The EyeArt identified all cases of vision-threatening retinopathy in the standard images.
Conclusion: EyeArt identified diabetic retinopathy in EIDON images with similar sensitivity to standard images in a large-scale screening programme, exceeding the sensitivity threshold recommended for a screening test. Further work to optimise the identification of 'no retinopathy' and to understand the differential lesion detection in the two imaging systems would enhance the use of these two innovative technologies in a diabetic retinopathy screening setting.
Keywords: diagnostic tests/investigation; epidemiology; imaging; retina.
© Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.
Conflict of interest statement
Competing interests: None declared.
Similar articles
-
An observational study to assess if automated diabetic retinopathy image assessment software can replace one or more steps of manual imaging grading and to determine their cost-effectiveness.Health Technol Assess. 2016 Dec;20(92):1-72. doi: 10.3310/hta20920. Health Technol Assess. 2016. PMID: 27981917 Free PMC article.
-
Comparison of true-colour wide-field confocal scanner imaging with standard fundus photography for diabetic retinopathy screening.Br J Ophthalmol. 2020 Nov;104(11):1579-1584. doi: 10.1136/bjophthalmol-2019-315269. Epub 2020 Mar 4. Br J Ophthalmol. 2020. PMID: 32139499
-
Prospective evaluation of an artificial intelligence-enabled algorithm for automated diabetic retinopathy screening of 30 000 patients.Br J Ophthalmol. 2021 May;105(5):723-728. doi: 10.1136/bjophthalmol-2020-316594. Epub 2020 Jun 30. Br J Ophthalmol. 2021. PMID: 32606081 Free PMC article.
-
Crowdsourcing and Automated Retinal Image Analysis for Diabetic Retinopathy.Curr Diab Rep. 2017 Sep 23;17(11):106. doi: 10.1007/s11892-017-0940-x. Curr Diab Rep. 2017. PMID: 28942485 Review.
-
The value of digital imaging in diabetic retinopathy.Health Technol Assess. 2003;7(30):1-119. doi: 10.3310/hta7300. Health Technol Assess. 2003. PMID: 14604499 Review.
Cited by
-
Protocol for a systematic review and meta-analysis of the diagnostic accuracy of artificial intelligence for grading of ophthalmology imaging modalities.Diagn Progn Res. 2022 Jul 14;6(1):15. doi: 10.1186/s41512-022-00127-9. Diagn Progn Res. 2022. PMID: 35831880 Free PMC article.
-
Transparency in Artificial Intelligence Reporting in Ophthalmology-A Scoping Review.Ophthalmol Sci. 2024 Jan 18;4(4):100471. doi: 10.1016/j.xops.2024.100471. eCollection 2024 Jul-Aug. Ophthalmol Sci. 2024. PMID: 38591048 Free PMC article.
-
Test accuracy of artificial intelligence-based grading of fundus images in diabetic retinopathy screening: A systematic review.J Med Screen. 2023 Sep;30(3):97-112. doi: 10.1177/09691413221144382. Epub 2023 Jan 9. J Med Screen. 2023. PMID: 36617971 Free PMC article.
-
Patient and Provider Experience with Artificial Intelligence Screening Technology for Diabetic Retinopathy in a Rural Primary Care Setting.J Maine Med Cent. 2023 Summer;5(2):2. doi: 10.46804/2641-2225.1144. Epub 2023 Apr 20. J Maine Med Cent. 2023. PMID: 39118821 Free PMC article.
-
Recent Advances and Clinical Application of Color Scanning Laser Ophthalmoscope.J Clin Med. 2021 Feb 11;10(4):718. doi: 10.3390/jcm10040718. J Clin Med. 2021. PMID: 33670287 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical