Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Oct:135:107542.
doi: 10.1016/j.bioelechem.2020.107542. Epub 2020 May 1.

A novel electrochemical immunosensor for the highly sensitive and selective detection of the depression marker human apolipoprotein A4

Affiliations

A novel electrochemical immunosensor for the highly sensitive and selective detection of the depression marker human apolipoprotein A4

Bolu Sun et al. Bioelectrochemistry. 2020 Oct.

Abstract

The fabrication of electrochemical biosensors to directly, rapidly and ultrasensitively detect disease markers in urine or blood samples has become a new and competitive challenge in the field of sensor research. In this paper, a novel electrochemical immunosensor with high selectivity and sensitivity for the detection of the depression marker human apolipoprotein A4 (Apo-A4) was successfully constructed using zeolite imidazole ester metal organic skeleton-nitrogen doped graphene composites (ZIF-8@N-Gr). To this end, because of the higher surface area and biocompatibility, ZIF-8 with abundant biomolecular binding sites provided a good microenvironment for effectively immobilizing antigens. ZIF-8@N-Gr presented a flake structure, as the electrode displayed excellent electrical conductivity, which enhanced the electron transfer and significantly amplified the current signal of the immunosensor. More importantly, these immunosensors are capable of assaying human apolipoprotein A4 (Apo-A4) in 100% serum without suffering from any significant biological interference. Under optimized experimental conditions, the sensor was used for the analysis of whole serum samples and presented a wide linear range from 1.47 × 10-10 g/mL to 3.00 × 10-7 g/mL with a low detection limit of 8.33 × 10-11 g/mL (3σ, n = 15). The satisfactory results of human serum sample analysis indicated that the proposed immunosensor had promising potential in the clinical diagnosis of depression.

Keywords: Apolipoprotein A4; Depression markers; Electrochemical immunosensor.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources