. 2020 Jun;39(5):1515-1522.
doi: 10.1002/nau.24386. Epub 2020 May 11.

Valsalva urethral profile (VUP): A urodynamic measure to assess stress urinary incontinence in women

Affiliations

Valsalva urethral profile (VUP): A urodynamic measure to assess stress urinary incontinence in women

Philippe Dompeyre et al. Neurourol Urodyn. 2020 Jun.

Abstract

Aims: We aimed to assess the value of the Valsalva urethral profile (VUP) in case of stress urinary incontinence (SUI).

Methods: Six hundred and ninety-four women without pelvic organ prolapse were included in this prospective monocentric study. SUI was diagnosed from symptoms using the International Continence Society definition, and severity using two validated questionnaires (USP and ICIQ-SF). The urodynamic parameters studied were maximal urethral closure pressure (MUCP) and functional length (FL). Both were performed at rest, during a Valsalva maneuver (v-MUCP and v-FL) and again at rest. Correlation analyses and ROC curves were used to assess the value of the clinical and urodynamic measurements.

Results: In our population, based on the questionnaires, 172 (24.8%) women were diagnosed with pure SUI on symptoms, 71 (10.2%) with urgency urinary incontinence and 392 (56.5%) with mixed urinary incontinence; 59 (8.5%) women were continent. The v-MUCP was the most correlated parameter to the severity of SUI (ρ: -0.63) and the most predictive of SUI risk, with a threshold value of 35 cm H2 O (Se = 0.82, Sp = 0.86). The v-FL was significantly shortened in case of SUI.

Conclusions: The v-MUCP and v-FL are global measurements of urethral resistance during stress. With a threshold value of 35 cm H2 O, the v-MUCP was the most discriminating parameter for the diagnosis of SUI, with a good reliability.

Keywords: MUCP; bladder neck mobility; stress urinary incontinence; urodynamics.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. DeLancey JOL, Trowbridge ER, Miller JM, et al. Stress urinary incontinence: relative importance of urethral support and urethral closure pressure. J Urol. 2008;179:2286-2290.
    1. Bump RC, Elser DM, Theofrastous JP, McClish DK. Valsalva leak point pressures in women with genuine stress incontinence: reproducibility, effect of catheter caliber, and correlations with other measures of urethral resistance. Am J Obstet Gynecol. 1995;173:551-557.
    1. McGuire EJ, Fitzpatrick CC, Wan J, et al. Clinical assessment of urethral sphincter function. J Urol. 1993;150:1452-1454.
    1. Theofrastous JP, Bump RC, Elser DM, Wyman JF, McClish DK. Correlation of urodynamic measures of urethral resistance with clinical measures of incontinence severity in women with pure genuine stress incontinence. The Continence Program for Women Research Group. Am J Obstet Gynecol. 1995;173:407-412.
    1. Haab F, Ciofu C, Pedron P, et al. Feasibility of "Valsalva leak point pressure". Prospective study. Prog Urol. 1997;7:611-614.