Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jul;103(1_Suppl):42-49.
doi: 10.4269/ajtmh.19-0788.

Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections

Affiliations

Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections

Daniel G Colley et al. Am J Trop Med Hyg. 2020 Jul.

Abstract

Efforts to control Schistosoma mansoni infection depend on the ability of programs to effectively detect and quantify infection levels and adjust programmatic approaches based on these levels and program goals. One of the three major objectives of the Schistosomiasis Consortium for Operational Research and Evaluation (SCORE) has been to develop and/or evaluate tools that would assist Neglected Tropical Disease program managers in accomplishing this fundamental task. The advent of a widely available point-of-care (POC) assay to detect schistosome circulating cathodic antigen (CCA) in urine with a rapid diagnostic test (the POC-CCA) in 2008 led SCORE and others to conduct multiple evaluations of this assay, comparing it with the Kato-Katz (KK) stool microscopy assay-the standard used for more than 45 years. This article describes multiple SCORE-funded studies comparing the POC-CCA and KK assays, the pros and cons of these assays, the use of the POC-CCA assay for mapping of S. mansoni infections in areas across the spectrum of prevalence levels, and the validation and recognition that the POC-CCA, although not infallible, is a highly useful tool to detect low-intensity infections in low-to-moderate prevalence areas. Such an assay is critical, as control programs succeed in driving down prevalence and intensity and seek to either maintain control or move to elimination of transmission of S. mansoni.

PubMed Disclaimer

References

    1. Katz N, Chaves A, Pellegrino J, 1972. A simple device for quantitative stool thick-smear technique in schistosomiasis mansoni. Rev Inst Med Trop Sao Paulo 14: 397–400. - PubMed
    1. de Vlas SJ, Gryseels B, 1992. Underestimation of Schistosoma mansoni prevalences. Parasitol Today 8: 274–277. - PubMed
    1. de Vlas SJ, Gryseels B, van Oortmarssen GJ, Polderman AM, Habbema JD, 1993. A pocket chart to estimate true Schistosoma mansoni prevalences. Parasitol Today 9: 305–307. - PubMed
    1. Deelder AM, et al. 1994. Quantitative diagnosis of Schistosoma infections by measurement of circulating antigens in serum and urine. Trop Geogr Med 46: 233–238. - PubMed
    1. Stothard JR, Kabatereine NB, Tukahebwa EM, Kazibwe F, Rollinson D, Mathieson W, Webster JP, Fenwick A, 2006. Use of circulating cathodic antigen (CCA) dipsticks for detection of intestinal and urinary schistosomiasis. Acta Trop 97: 219–228. - PubMed

Publication types