Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Nov;42(11):3543-3573.
doi: 10.1007/s10653-020-00589-0. Epub 2020 May 13.

Estimation of indoor air pollutant during photocopy/printing operation: a computational fluid dynamics (CFD)-based study

Affiliations

Estimation of indoor air pollutant during photocopy/printing operation: a computational fluid dynamics (CFD)-based study

Abhishek Nandan et al. Environ Geochem Health. 2020 Nov.

Abstract

Population form a homeostat with environment where they live and exchange continuous gas for their respiration, which is the primary pathway for the pollutants to enter into human metabolism. The pollution present indoor is due to multiple sources like electronic and electrical equipment, clothes, furniture and other anthropogenic activity. The concentration of these pollutants changes with time and depends mainly on source type (continuous/intermittent), time of the operation and release/ventilation/wind velocity/pollutant dispersion and anthropogenic activity. It has been observed that equipment like printers, printing machines, photocopiers, etc., releases several pollutants like volatile organic compounds (VOCs), ozone (O3), semi-volatile organic compounds, benzene (C6H6), toluene and suspended particulate matter during operation. This work represents the emissions of VOCs, benzene, and toluene during photocopy. The numerical validation of results was done using Fluent, which is an application-based software which helps in physical modeling describing air flow and effect of multiple parameter on it like temperature and no of printing/photocopy (in proposed experiment) with respect to time. It has been observed from the results that the emissions of VOCs, benzene, and toluene increase from 0.09 to 1.13 PPM, 0.17 to 1.87 PPM and 30 to 235 PPM, respectively, as the operating duration, temperature (35-40 °C) and rate of printing/photocopying increase (120-200/h), and it is because printer/photocopy machine uses heat and pressure to fix an image on the paper surface which subsequently result in higher emission. Multiple adverse health, safety and environmental impacts due to operation of photocopy/printing call for in-depth study, guidance, and monitoring of the workers occupationally associated with this operation for their well-being.

Keywords: Indoor air pollution; Occupational health; Photocopy operation; VOC emission.

PubMed Disclaimer

LinkOut - more resources