Electrocardiographic interpretation of pacemaker algorithms enabling minimal ventricular pacing
- PMID: 32413512
- DOI: 10.1016/j.hrthm.2020.05.012
Electrocardiographic interpretation of pacemaker algorithms enabling minimal ventricular pacing
Abstract
Cardiac pacing from the apex of the right ventricle has been shown to result in left ventricular dysfunction, atrial fibrillation, and increased mortality. To counter these effects, one of the strategies developed is avoidance of ventricular pacing when not necessary, using programmable algorithms to minimize ventricular pacing. Seven algorithms are available from 5 manufacturers. Four of the manufacturers have mode conversion algorithms that pace AAI(R) but, in the presence of failed atrioventricular (AV) conduction, demonstrate algorithm-offset and convert to DDD(R) with ventricular pacing. Three manufacturers do not have mode conversion but rather AV extension to encourage AV conduction. Each of these algorithms has a unique design and, when ventricular pacing is present, will regularly schedule conduction testing to encourage AV conduction and hence algorithm-onset. All of these algorithms seem to violate the rule of AV conduction by allowing the AV delay for sensed ventricular events to be longer than for ventricular paced events. The result is frequently bizarre electrocardiographic (ECG) appearances that often are unique to the company's algorithm but also suggest pacemaker malfunction. This review highlights and illustrates the features of these algorithms as they appear on ECG, and discusses other situations that result in unintended ventricular pacing.
Keywords: Atrioventricular delay; Cardiac failure; Electrocardiography; Minimize ventricular pacing; Pacemaker algorithms; Pacemaker programming.
Crown Copyright © 2020. Published by Elsevier Inc. All rights reserved.
Similar articles
-
An optimized AV delay algorithm for patients with intermittent atrioventricular conduction.Pacing Clin Electrophysiol. 1998 May;21(5):1035-43. doi: 10.1111/j.1540-8159.1998.tb00149.x. Pacing Clin Electrophysiol. 1998. PMID: 9604235
-
Effect of atrioventricular sequential pacing in patients with no ventriculoatrial conduction.J Am Coll Cardiol. 1984 Aug;4(2):273-7. doi: 10.1016/s0735-1097(84)80213-2. J Am Coll Cardiol. 1984. PMID: 6736468
-
Performance of a specific algorithm to minimize right ventricular pacing: A multicenter study.Heart Rhythm. 2016 Jun;13(6):1266-73. doi: 10.1016/j.hrthm.2016.02.008. Epub 2016 Feb 17. Heart Rhythm. 2016. PMID: 26899544 Clinical Trial.
-
AAI pacing mode: when is it indicated and how should it be achieved?Clin Cardiol. 1993 Apr;16(4):339-43. doi: 10.1002/clc.4960160409. Clin Cardiol. 1993. PMID: 8458114 Review.
-
DDD pacing and interatrial conduction block: importance of optimal AV interval setting.Pacing Clin Electrophysiol. 2000 Sep;23(9):1448-50. doi: 10.1111/j.1540-8159.2000.tb00981.x. Pacing Clin Electrophysiol. 2000. PMID: 11025908 Review.
Cited by
-
Short-term effect of low atrial septum pacing on new-onset atrial fibrillation in patients with sinus node dysfunction a prospective randomized single-center study.Ann Med Surg (Lond). 2025 May 26;87(7):4096-4104. doi: 10.1097/MS9.0000000000003362. eCollection 2025 Jul. Ann Med Surg (Lond). 2025. PMID: 40852001 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous