Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2020 Nov;75(11):1529-1539.
doi: 10.1111/anae.15041. Epub 2020 May 16.

Tracheal tube size in adults undergoing elective surgery - a narrative review

Affiliations
Free article
Review

Tracheal tube size in adults undergoing elective surgery - a narrative review

S Karmali et al. Anaesthesia. 2020 Nov.
Free article

Abstract

Tracheal tubes are routinely used in adults undergoing elective surgery. The size of the tracheal tube, defined by its internal diameter, is often generically selected according to sex, with 7-7.5 mm and 8-8.5 mm tubes recommended in women and men, respectively. Tracheal diameter in adults is highly variable, being narrowest at the subglottis, and is affected by height and sex. The outer diameter of routinely used tracheal tubes may exceed these dimensions, traumatise the airway and increase the risk of postoperative sore throat and hoarseness. These complications disproportionately affect women and may be mitigated by using smaller tracheal tubes (6-6.5 mm). Patient safety concerns about using small tracheal tubes are based on critical care populations undergoing prolonged periods of tracheal intubation and not patients undergoing elective surgery. The internal diameter of the tube corresponds to its clinical utility. Tracheal tubes as small as 6.0 mm will accommodate routinely used intubation aids, suction devices and slim-line fibreoptic bronchoscopes. Positive pressure ventilation may be performed without increasing the risk of ventilator-induced lung injury or air trapping, even when high minute volumes are required. There is also no demonstrable increased risk of aspiration or cuff pressure damage when using smaller tracheal tubes. Small tracheal tubes may not be safe in all patients, such as those with high secretion loads and airflow limitation. A balanced view of risks and benefits should be taken appropriate to the clinical context, to select the smallest tracheal tube that permits safe peri-operative management.

Keywords: airway injury; postoperative complications; size; tracheal tube.

PubMed Disclaimer

References

    1. Cook TM, Woodall N, Frerk C, Project FNA. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. British Journal of Anaesthesia 2011; 106: 617-31.
    1. Zias N, Chroneou A, Tabba MK, et al. Post tracheostomy and post intubation tracheal stenosis: report of 31 cases and review of the literature. BMC Pulmonary Medicine 2008; 8: 18.
    1. Hillel AT, Karatayli-Ozgursoy S, Samad I, et al. Predictors of posterior glottic stenosis: a multi-institutional case-control study. Annals of Otology Rhinolology and Laryngology 2016; 125: 257-63.
    1. Koshkareva Y, Gaughan JP, Soliman AM. Risk factors for adult laryngotracheal stenosis: a review of 74 cases. Annals of Otology Rhinology and Laryngology 2007; 116: 206-10.
    1. Avrahami E, Frishman E, Spierer I, Englender M, Katz R. CT of minor intubation trauma with clinical correlations. European Journal of Radiology 1995; 20: 68-71.

MeSH terms