Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jul 1:265:110529.
doi: 10.1016/j.jenvman.2020.110529. Epub 2020 Apr 11.

Pulsed electric field application reduces carbapenem- and colistin-resistant microbiota and blaKPC spread in urban wastewater

Affiliations

Pulsed electric field application reduces carbapenem- and colistin-resistant microbiota and blaKPC spread in urban wastewater

Gregory A Ballash et al. J Environ Manage. .

Abstract

Wastewater flows from metropolitan areas, especially those with healthcare inputs, can serve as transport reservoirs for the dissemination of clinically-relevant antimicrobial resistant bacteria (ARB) such as carbapenem- (CR) and colistin-resistant (CoR) strains. Pulsed electric field (PEF) is an emerging wastewater management tool for reducing bacterial loads without generating environmentally harmful byproducts, but it's ability to reduce ARB and their genetic determinants is not well reported. We collected 86, 10-L raw wastewater influent samples from a large metropolitan wastewater treatment plant in Columbus, Ohio and subjected them to low (34 kV cm-1 for 67 μsec) and high (36 kV cm-1 for 89 μsec) PEF treatment. We quantified the PEF effectiveness by measuring concentrations of total coliform bacteria, CR and CoR bacteria, and the epidemic carbapenemase gene, blaKPC, before and after PEF treatment. Utilizing marginal linear regression models with generalized estimating equations, we observed that low and high PEF treatment resulted in a 1.94 (95% CI 2.06-1.81; P < 0.001) and 2.32 (95% CI 2.46-2.18; P < 0.001) log reduction of total coliform bacteria concentrations, respectively. Low and high PEF treatment produced similar log reductions between CR E. coli (2.01 (95% CI 2.15-1.86; P < 0.001); 2.14 (95% CI: 5.30-4.61; P < 0.001)) and CR Enterobacteriaceae concentrations (1.55 (95% CI 1.70-1.41; P < 0.001); 1.86 (95% CI 2.05-1.68; P < 0.001)), and resulted in a 1.15 log (95% CI 1.38-0.93, P < 0.001) and 1.28 log (95% CI 1.54-1.03, P < 0.001) reduction of absolute blaKPC concentrations. Log CoR E. coli concentrations were reduced by 2.47 (95% CI 2.78-2.15; P < 0.001) and 2.52 (95% CI 2.91-2.15; P < 0.001) and CoR Enterobacteriaceae by 2.24 (95% CI 2.52-1.95; P < 0.001) and 2.50 (95% CI 2.89-2.11; P < 0.001) following low and high PEF application. PEF can be applied for wastewater management as an independent treatment method, particularly at critical control points, such as an on-site management of wastewater from hospitals or other healthcare facilities, or in series with other conventional methods to reduce total bacterial loads and concentrations of clinically-relevant ARB.

Keywords: Carbapenem- and colistin-resistance; Enterobacteriaceae; Pulsed electric field; Wastewater influent; bla(KPC).

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The authors declare no conflict of interest.

LinkOut - more resources