Multicenter Study
. 2020 Oct 25;58(11):1921-1930.
doi: 10.1515/cclm-2020-0130.

Quality performance for indirect Xa inhibitor monitoring in patients using international external quality data

Affiliations
Multicenter Study

Quality performance for indirect Xa inhibitor monitoring in patients using international external quality data

Martine J Hollestelle et al. Clin Chem Lab Med. .

Abstract

Objectives Chromogenic anti-activated factor X (FXa) assays are currently the "gold standard" for monitoring indirect anticoagulants. However, anti-FXa has been shown to vary according to the choice of reagents. In the present study, the performance of anti-FXa measurement was evaluated in order to gain more insight into the clinical applications. Furthermore, the longitudinal coefficient of variation (CV) was studied to investigate whether there is improvement over time. Methods Laboratory tests results were evaluated for samples spiked with unfractionated heparin (UFH), low-molecular-weight-heparin (LMWH), fondaparinux and danaparoid sodium. External quality assessment (EQA) data from multiple years were used from more than 100 laboratories. Results Comparison of the results for all methods showed significant differences in measured values between the frequently used methods (ANOVA: p < 0.001). The largest differences were observed for LMWH and UFH measurements. These differences may be caused by differences in method composition, such as the addition of dextran sulphate. Substantial interlaboratory variation in anti-FXa monitoring was observed for all parameters, particularly at low concentrations. Our results showed that below 0.35 IU/mL, the CVs for UFH and LMWH increase dramatically and results below this limit should be used with caution. Conclusions Our study demonstrates that the choice of the anti-FXa method is particularly important for UFH and LMWH measurement. The variation in measurements may have an effect on clinical implications, such as therapeutic ranges. Furthermore, the longitudinal EQA data demonstrated a constant performance and, in at least 50% of the cases, improvement in the CV% of the anti-Xa results over time.

Keywords: anti-FXa; danaparoid sodium; external quality assurance; fondaparinux; low-molecular-weight-heparin (LMWH); unfractionated heparin (UFH).

PubMed Disclaimer

References

    1. Garcia DA, Baglin TP, Weitz JI, Samama MM. Parenteral anticoagulants: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e24S–43S.
    1. Harenberg J. Is laboratory monitoring of low-molecular-weight heparin therapy necessary? Yes. J Thromb Haemost 2004;2:547–50.
    1. Bounameaux H, de Moerloose P. Is laboratory monitoring of low-molecular-weight heparin therapy necessary? No. J Thromb Haemost 2004;2:551–4.
    1. Shojania AM. More on: is laboratory monitoring of low-molecular-weight heparin necessary? J Thromb Haemost 2004;2:2276–7.
    1. Bates SM, Greer IA, Middeldorp S, Veenstra DL, Prabulos AM, Vandvik PO. VTE, thrombophilia, antithrombotic therapy, and pregnancy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141:e691S–736S.

Publication types

LinkOut - more resources