Ultrasound-guided venipuncture for implantation of cardiac implantable electronic devices: A single-center, retrospective study
- PMID: 32452043
- DOI: 10.1111/pace.13961
Ultrasound-guided venipuncture for implantation of cardiac implantable electronic devices: A single-center, retrospective study
Abstract
Background: The venous access for the insertion of permanent leads of cardiac implantable electronic devices is often achieved by venous cutdown of the cephalic vein, or by "blind" puncture of the subclavian vein using anatomical landmarks, or by fluoroscopy-assisted methods.
Methods: We have retrospectively analyzed our clinical experience to verify the feasibility, the safety, and efficacy of the adoption of ultrasound-guided puncture/cannulation of the axillary vein for this purpose.
Results: Nine hundred eighty-seven leads were placed during 548 consecutive procedures, accessing the axillary vein in the infraclavicular area using real-time ultrasound guidance. Venipuncture was successful in 99.8% of cases. The access time was 11 seconds (range 4-580). We recorded three cases of pneumothorax (0.5%), but no hemothorax and no hemo-mediastinum. The incidence of local hematoma was 2.1% (12 cases). No injury to the brachial plexus or to the phrenic nerve was recorded. In a follow-up of 33 months (range 16-39), we observed no cases of "subclavian crush syndrome" (damage of the leads at the level of the thoracic inlet), and the rate of pocket infection/infective endocarditis was 0.7%.
Conclusion: In our experience, ultrasound-guided puncture/cannulation of the axillary vein for implantation of permanent leads is feasible, effective, and safe. It might be considered as a first option for this procedure.
© 2020 Wiley Periodicals LLC.
References
REFERENCES
-
- Littleford PO, Parsonnet V, Spector VD. Method for the rapid and atraumatic insertion of permanent endocardial pacemaker electrodes through subclavian vein. Am J Cardiol. 1979;43:980-982.
-
- Gallik DM, Ben-Zur UM, Gross SN, Furman S. Lead fracture in cephalic versus subclavian approach with transvenous implantable cardioverter defibrillator systems. Pacing Clin Electrophysiol. 1996;19:1089-1094.
-
- Lau EW. Upper body venous access for transvenous lead placement-review of existent techniques. Pacing Clin Electrophysiol. 2007;30:901-909.
-
- Magney JE, Staplin DH, Hunter DW. A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous occlusion. Pacing Clin Electrophysiol. 1993;16:2133-2142.
-
- Migliore F, Siciliano M, De Lazzari M, et al. Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads. J Interv Card Electrophysiol. 2015;43:263-267.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
