Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan;93(1):174-182.e2.
doi: 10.1016/j.gie.2020.05.020. Epub 2020 May 25.

Impact of various central endoscopy reading models on treatment outcome in Crohn's disease using data from the randomized, controlled, exploratory cohort arm of the BERGAMOT trial

Affiliations

Impact of various central endoscopy reading models on treatment outcome in Crohn's disease using data from the randomized, controlled, exploratory cohort arm of the BERGAMOT trial

Walter Reinisch et al. Gastrointest Endosc. 2021 Jan.

Abstract

Background and aims: Endoscopic assessment of mucosal appearance by independent central reading has become the standard method to assess Crohn's disease activity in clinical trials. The performance characteristics of various endoscopy reading models have yet to be systematically evaluated.

Methods: This substudy included patients with Crohn's disease in the exploratory induction cohort of the BERGAMOT trial (NCT02394028) randomly assigned to etrolizumab or placebo. Endoscopies conducted at baseline and week 14 were independently scored using the Simple Endoscopic Score for Crohn's Disease (SES-CD) by a local reader (LR) and 2 central readers (CRs). Five endoscopy reading models were compared: single LR, single CR, average of 2 CRs, and 2 models incorporating the LR and 1 or 2 CRs depending on alignment between the LR and the CR, defined according to a sliding scale applied to a range of scores.

Results: Five hundred thirty-five videos were scored. Models involving 2 readers demonstrated lower placebo rates (3.4%) than the single LR (11.9%) and the single CR (6.8%) models. Treatment effect size based on endoscopic improvement (≥50% reduction in SES-CD from baseline) was highest with the 2 models incorporating the LR and 1 or 2 CRs (Δ = 16.2%). Further, in the etrolizumab arm, models with 2 readers demonstrated the lowest variability for the SES-CD.

Conclusions: Central endoscopy reading models in Crohn's disease have an impact on placebo response rates and effect size. Incorporating the LR appears to be important because models using both CRs and LRs resulted in the greatest treatment effect size for endoscopic improvement with etrolizumab, lower placebo rates, and reduced variability.

PubMed Disclaimer

Comment in

Associated data

LinkOut - more resources