Evaluating feasibility of high resolution T1-perfusion MRI with whole brain coverage using compressed SENSE: Application to glioma grading
- PMID: 32464580
- DOI: 10.1016/j.ejrad.2020.109049
Evaluating feasibility of high resolution T1-perfusion MRI with whole brain coverage using compressed SENSE: Application to glioma grading
Abstract
Purpose: To evaluate the efficacy of optimized T1-Perfusion MRI protocol (protocol-2) with whole brain coverage and improved spatial resolution using Compressed-SENSE (CSENSE) to differentiate high-grade-glioma (HGG) and low-grade-glioma (LGG) and to compare it with the conventional protocol (protocol-1) with partial brain coverage used in our center.
Methods: This study included MRI data from 5 healthy volunteers, a phantom and 126 brain tumor patients. Current study had two parts: To analyze the effect of CSENSE on 3D-T1-weighted (W) fast-field-echo (FFE) images, T1-W, dual-PDT2-W turbo-spin-echo images and T1 maps, and to evaluate the performance of high resolution T1-Perfusion MRI protocol with whole brain coverage optimized using CSENSE. Coefficient-of-Variation (COV), Relative-Percentage-Error (RPE), Normalized-Mean-Squared-Error (NMSE) and qualitative scoring were used for the former study. Tracer-kinetic (Ktrans,ve,vp) and hemodynamic (rCBV,rCBF) parameters computed from both protocols were used to differentiate LGG and HGG.
Results: The image quality of all structural images was found to be of diagnostic quality till R = 4. NMSE in healthy T1-W-FFE images and COV in phantom images increased with-respect-to R and images provided optimum quality till R = 4. Structural images and maps exhibited artefacts from R = 6. All parameters in tumor tissue and hemodynamic parameters in healthy gray matter tissue computed from both protocols were not significantly different. Parameters computed from protocol-2 performed better in terms of glioma grading. For both protocols, rCBF performed least (AUC = 0.759 and 0.851) and combination of all parameters performed best (AUC = 0.890 and 0.964).
Conclusion: CSENSE (R = 4) can be used to improve the resolution and brain coverage for T1-Perfusion analysis used to differentiate gliomas.
Keywords: Compressed-SENSE; DCE-MRI; Glioma grading; T1-Perfusion MRI.
Copyright © 2020 Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of competing interest None.
Similar articles
-
Glioma grading using a machine-learning framework based on optimized features obtained from T1 perfusion MRI and volumes of tumor components.J Magn Reson Imaging. 2019 Oct;50(4):1295-1306. doi: 10.1002/jmri.26704. Epub 2019 Mar 20. J Magn Reson Imaging. 2019. PMID: 30895704
-
Textural features of dynamic contrast-enhanced MRI derived model-free and model-based parameter maps in glioma grading.J Magn Reson Imaging. 2018 Apr;47(4):1099-1111. doi: 10.1002/jmri.25835. Epub 2017 Aug 28. J Magn Reson Imaging. 2018. PMID: 28845594
-
Dynamic contrast-enhanced and dynamic susceptibility contrast perfusion MR imaging for glioma grading: Preliminary comparison of vessel compartment and permeability parameters using hotspot and histogram analysis.Eur J Radiol. 2016 Jun;85(6):1147-56. doi: 10.1016/j.ejrad.2016.03.020. Epub 2016 Mar 22. Eur J Radiol. 2016. PMID: 27161065
-
An evidence-based approach to assess the accuracy of intravoxel incoherent motion imaging for the grading of brain tumors.Medicine (Baltimore). 2018 Nov;97(45):e13217. doi: 10.1097/MD.0000000000013217. Medicine (Baltimore). 2018. PMID: 30407363 Free PMC article. Review.
-
An evidence-based approach to evaluate the accuracy of amide proton transfer-weighted MRI in characterization of gliomas.Medicine (Baltimore). 2019 Mar;98(10):e14768. doi: 10.1097/MD.0000000000014768. Medicine (Baltimore). 2019. PMID: 30855481 Free PMC article.
Cited by
-
Advanced Diagnosis of Glioma by Using Emerging Magnetic Resonance Sequences.Front Oncol. 2021 Aug 5;11:694498. doi: 10.3389/fonc.2021.694498. eCollection 2021. Front Oncol. 2021. PMID: 34422648 Free PMC article. Review.
-
Compressed Sensitivity Encoding Artificial Intelligence Accelerates Brain Metastasis Imaging by Optimizing Image Quality and Reducing Scan Time.AJNR Am J Neuroradiol. 2024 Apr 8;45(4):444-452. doi: 10.3174/ajnr.A8161. AJNR Am J Neuroradiol. 2024. PMID: 38485196 Free PMC article.
-
Compressed SENSitivity Encoding (SENSE): Qualitative and Quantitative Analysis.Diagnostics (Basel). 2024 Aug 5;14(15):1693. doi: 10.3390/diagnostics14151693. Diagnostics (Basel). 2024. PMID: 39125569 Free PMC article.
-
Hemodynamic Imaging in Cerebral Diffuse Glioma-Part A: Concept, Differential Diagnosis and Tumor Grading.Cancers (Basel). 2022 Mar 10;14(6):1432. doi: 10.3390/cancers14061432. Cancers (Basel). 2022. PMID: 35326580 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical