Incidence, predictors and outcomes of valve-in-valve TAVI: A systematic review and meta-analysis
- PMID: 32470529
- DOI: 10.1016/j.ijcard.2020.05.058
Incidence, predictors and outcomes of valve-in-valve TAVI: A systematic review and meta-analysis
Abstract
Aims: Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease before the arrival of transcatheter aortic valve replacement (TAVI), although limited by degeneration of the bioprosthesis. "Redo" intervention itself is burdened by high risk of complications and valve-in-valve (ViV) TAVI could be a valid strategy of redo for patients with comorbidities.
Methods and results: Two independent reviewers screened all studies investigating patients undergoing ViV TAVI. Mortality at 30 days and at 1 year was the primary end point. Of 286 studies identified, 26 articles were included in this review with a total of 1448 patients. Median age was 78.8 years, 57.7% male. Median STS score and Logistic EuroSCORE were 9.4% and 31.3% respectively. Stenosis (45%) was the leading cause of prosthesis failure. Transfemoral approach was preferred (76%), with a prevalence of balloon expandable valves (73.3%). Mean follow up was 376 days. Overall and cardiovascular mortality at 30 days was 6.5% and 5.5% respectively, while at 1 year it was 14.5% and 8.9% respectively. At meta-regression analysis study year (p < .001), Logistic EuroSCORE (p < .01) and valve diameter ≤ 21 mm (p < .05) at 30 days, and stenosis as reason for failure (p = .05) at 1 year were identified as possible predictors of survival.
Conclusions: ViV TAVI offers a valid strategy to treat high risk patients with a failure of bioprosthesis with satisfying results in terms of short and mid-term mortality. Future studies are needed to find predictors of long term survival and outcomes in lower risk patients.
Keywords: Aortic stenosis; Heart team; Transcatheter aortic valve implantation; Valve-in-valve.
Copyright © 2020 Elsevier B.V. All rights reserved.
Comment in
-
Re-intervention for failed surgical aortic bioprosthesis: Remaining questions on long term outcomes and selection of patients.Int J Cardiol. 2021 Jan 15;323:242. doi: 10.1016/j.ijcard.2020.09.006. Epub 2020 Sep 16. Int J Cardiol. 2021. PMID: 32916224 No abstract available.
-
Reply to "Re-intervention for failed surgical aortic bioprosthesis: Remaining questions on long term outcomes and selection of patients".Int J Cardiol. 2021 Mar 1;326:155. doi: 10.1016/j.ijcard.2020.10.023. Epub 2020 Oct 11. Int J Cardiol. 2021. PMID: 33053392 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical