Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Nov;52(11):988-994.
doi: 10.1055/a-1180-8614. Epub 2020 Jun 4.

Endoscopic ultrasound-guided fine-needle aspiration for the diagnosis and grading of pancreatic neuroendocrine tumors: a retrospective analysis of 110 cases

Affiliations

Endoscopic ultrasound-guided fine-needle aspiration for the diagnosis and grading of pancreatic neuroendocrine tumors: a retrospective analysis of 110 cases

Salvatore Paiella et al. Endoscopy. 2020 Nov.

Abstract

Background: Data on the reliability of the Ki-67 index and grading calculations from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of pancreatic neuroendocrine tumors (PanNETs) are controversial. We aimed to assess the accuracy of these data compared with histology.

Methods: Cytological analysis from EUS-FNA in patients with suspected PanNETs (n = 110) were compared with resection samples at a single institution. A minimum of 2000 cells were considered to be adequate for grading. Correlation and agreement between cytology and histology in grading and Ki-67 values, respectively, were investigated. Secondary outcomes included the diagnostic performance of EUS-FNA.

Results: EUS-FNA samples were adequate for PanNET diagnosis and PanNET grading in 98/110 (89.1 %) and 77/110 (70.0 %) patients, respectively; thus, 77 samples were adequate for comparing cytology vs. histology. There were 67 (62.0 %), 40 (36.4 %), and 1 (0.9 %) patients with a final diagnosis of G1, G2, and G3 tumors, respectively. EUS-FNA grading was concordant with surgical pathology in 81.8 % of patients; under- and overgrading occurred in 15.6 % and 2.6 %, respectively. The overall level of agreement for grading was moderate (Cohen's κ = 0.59, 95 % confidence interval [CI] 0.34 - 0.78). Spearman's rho for Ki-67 in tumors ≤ 20 mm and > 20 mm was strong and moderate, respectively (rho = 0.68, 95 %CI 0.47 - 0.83; rho = 0.59, 95 %CI 0.35 - 0.75). The Bland - Altman plot showed that the Ki-67 values were comparable and reproducible between the two measurements.

Conclusions: Although they were not available for a significant number of patients, grading and Ki-67 values from cytology correlated with histology moderately to strongly.

PubMed Disclaimer

Conflict of interest statement

Dr. Scarpa is a speaker and consultant for Ypsen and Astra Zeneca. The remaining authors declare that they have no conflicts of interest.

Comment in

Publication types

MeSH terms

LinkOut - more resources