Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 Aug;75(8):1050-1058.
doi: 10.1111/anae.15056. Epub 2020 Jun 4.

Peri-operative administration of tranexamic acid in lower limb arthroplasty: a multicentre, prospective cohort study

Collaborators, Affiliations
Free article
Observational Study

Peri-operative administration of tranexamic acid in lower limb arthroplasty: a multicentre, prospective cohort study

T D Lloyd et al. Anaesthesia. 2020 Aug.
Free article

Abstract

In the UK, tranexamic acid is recommended for all surgical procedures where expected blood loss exceeds 500 ml. However, the optimal dose, route and timing of administration are not known. This study aimed to evaluate current practice of peri-operative tranexamic acid administration. Patients undergoing primary total hip arthroplasty, total knee arthroplasty or unicompartmental knee arthroplasty during a 2-week period were eligible for inclusion in this prospective study. The primary outcome was the proportion of patients receiving tranexamic acid in the peri-operative period. Secondary outcomes included: dose, route and timing of tranexamic acid administration; prevalence of pre- and postoperative anaemia; estimated blood loss; and red blood cell transfusion rates. In total, we recruited 1701 patients from 56 NHS hospitals. Out of these, 1523 (89.5%) patients received tranexamic acid and of those, 1052 (69.1%) received a single dose of 1000 mg intravenously either pre- or intra-operatively. Out of the 1701 patients, 571 (33.6%) and 1386 (81.5%) patients were anaemic (haemoglobin < 130 g.l-1 ) in the pre- and postoperative period, respectively. Mean (SD) estimated blood loss for all included patients was 792 (453) ml and 54 patients (3.1%) received a red blood cell transfusion postoperatively. The transfusion rate for patients with pre-operative anaemia was 6.5%, compared with 1.5% in patients without anaemia. Current standard of care in the UK is to administer 1000 mg of tranexamic intravenously either pre- or intra-operatively. Approximately one-third of patients present for surgery with anaemia, although the overall red blood cell transfusion rate is low. These data provide useful comparators when assessing the efficacy of tranexamic acid and other patient blood management interventions in future studies.

Keywords: anaemia; arthroplasty; blood loss; tranexamic acid; transfusion.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Park JH, Rasouli MR, Mortazavi SM, Tokarski AT, Maltenfort MG, Parvizi J. Predictors of perioperative blood loss in total joint arthroplasty. Journal of Bone and Joint Surgery 2013; 95: 1777-83.
    1. Greco NJ, Manocchio AG, Lombardi AV, Gao SL, Adams J, Berend KR. Should postoperative haemoglobin and potassium levels be checked routinely following blood-conserving primary total joint arthroplasty? Bone and Joint Journal 2019; 101-B: 25-31.
    1. Kim JL, Park JH, Han SB, Cho IY, Jang KM. Allogeneic blood transfusion is a significant risk factor for surgical-site infection following total hip and knee arthroplasty: a meta-analysis. Journal of Arthroplasty 2017; 32: 320-5.
    1. Everhart JS, Sojka JH, Mayerson JL, Glassman AH, Scharschmidt TJ. Perioperative allogeneic red blood-cell transfusion associated with surgical site infection after total hip and knee arthroplasty. Journal of Bone and Joint Surgery 2018; 100: 288-94.
    1. Shah A, Palmer AJR, Klein AA. Strategies to minimize intraoperative blood loss during major surgery. British Journal of Surgery 2020; 107: e26-38.

Publication types

MeSH terms

LinkOut - more resources