Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 Aug;30(8):912-921.
doi: 10.1111/pan.13909. Epub 2020 Jun 5.

Ventilation in pediatric anesthesia: A French multicenter prospective observational study (PEDIAVENT)

Affiliations
Observational Study

Ventilation in pediatric anesthesia: A French multicenter prospective observational study (PEDIAVENT)

Marion Lebossé et al. Paediatr Anaesth. 2020 Aug.

Abstract

Introduction: Protective ventilation is now a standard of care in adults. However, management of ventilation is heterogeneous in children and little is known regarding the mechanical ventilation parameters actually used during pediatric anesthesia.

Aim: The aim of the study was to assess current ventilatory practices during pediatric anesthesia in France and to compare them with pediatric experts' statements, with a specific focus on tidal volume.

Patients and methods: We conducted a prospective multicenter observational study, regarding the ventilatory management and the mechanical ventilation parameters, over two days (21 and 22 June 2017) in 29 pediatric centers in France. All children undergoing general anesthesia during these 2 days were eligible; those who required extracorporeal circulation or one-lung ventilation were excluded.

Results: A total of 701 children were included; median [IQR] age was 60 [24-120] months. Among the patients in whom controlled ventilation was used, 254/515 (49.3%) had an expired tidal volume >8 mL/kg and 44 children (8.8%) an expired tidal volume ≥10 mL/kg. Lower weight and use of a supraglottic airway device were significantly associated with provision of a tidal volume ≥10 mL/kg (odds ratio 0.94, 95% confidence interval [0.92; 0.97], P < .001 and 2.28 [1.20; 4.31], P = .012, respectively). The positive end-expiratory pressure was set at a median [IQR] of 4 [3-5] cmH2 O; it was <3 cmH2 O in 15.7% of children and not used in 56/499 (9.3%). Among intubated children, 57 (18.3%) received a tidal volume < 10 mL/kg with a positive end-expiratory pressure ≥3 cmH2 O in association with recruitment maneuvers.

Conclusions: Ventilatory practices in children were heterogenous, and a large proportion of children were not ventilated as it is currently recommended by some experts.

Keywords: mechanical ventilation; pediatric; positive end-expiratory pressure; tidal volume.

PubMed Disclaimer

References

REFERENCES

    1. Futier E, Constantin J-M, Paugam-Burtz C, et al. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. New Engl J Med. 2013;369:428-437.
    1. Young CC, Harris EM, Vacchiano C, et al. Lung-protective ventilation for the surgical patient: international expert panel-based consensus recommendations. Brit J Anesth. 2019;123:898-913.
    1. Thomas NJ, Jouvet P, Willson D. Acute lung injury in children-Kids really aren't just “Little Adults”. Pediatr Crit Care Med. 2013;14:429-432.
    1. KneyberMCJ ZH, Slutsky AS. Ventilator-induced lung injury. Similarity and differences between children and adults. Am J Resp Crit Care. 2014;190:258-265.
    1. Kneyber MCJ. Intraoperative mechanical ventilation for the pediatric patient. Best Pract Res Clin Anesthesiol. 2015;29:371-379.

Publication types

LinkOut - more resources