Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2020 May-Jun;9(3):186-193.
doi: 10.1097/APO.0000000000000293.

Update on Intraocular Lens Formulas and Calculations

Affiliations
Review

Update on Intraocular Lens Formulas and Calculations

Tina Xia et al. Asia Pac J Ophthalmol (Phila). 2020 May-Jun.

Abstract

Investigators, scientists, and physicians continue to develop new methods of intraocular lens (IOL) calculation to improve the refractive accuracy after cataract surgery. To gain more accurate prediction of IOL power, vergence lens formulas have incorporated additional biometric variables, such as anterior chamber depth, lens thickness, white-to-white measurement, and even age in some algorithms. Newer formulas diverge from their classic regression and vergence-based predecessors and increasingly utilize techniques such as exact ray-tracing data, more modern regression models, and artificial intelligence. This review provides an update on recent literature comparing the commonly used third- and fourth-generation IOL formulas with newer generation formulas. Refractive outcomes with newer formulas are increasingly more and more accurate, so it is important for ophthalmologists to be aware of the various options for choosing IOL power. Historically, refractive outcomes have been especially unpredictable in patients with unusual biometry, corneal ectasia, a history of refractive surgery, and in pediatric patients. Refractive outcomes in these patient populations are improving. Improved biometry technology is also allowing for improved refractive outcomes and surgery planning convenience with the availability of newer formulas on various biometry platforms. It is crucial for surgeons to understand and utilize the most accurate formulas for their patients to provide the highest quality of care.

PubMed Disclaimer

References

    1. An Y, Kang EK, Kim H, Kang MJ, Byun YS, Joo CK. Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study. BMC Ophthalmol 2019; 19:30. - PMC - PubMed
    1. Mylonas G, Sacu S, Buehl W, Ritter M, Georgopoulos M, Schmidt-Erfurth U. Performance of three biometry devices in patients with different grades of age-related cataract. Acta Ophthalmol 2011; 89:e237–e241. - PubMed
    1. Sheard R. Optimising biometry for best outcomes in cataract surgery. Eye (Lond) 2014; 28:118–125. - PMC - PubMed
    1. Fyodorov SN, Galin MA, Linksz A. Calculation of the optical power of intraocular lenses. Invest Ophthalmol 1975; 14:625–628. - PubMed
    1. Barrett GD. An improved universal theoretical formula for intraocular lens power prediction. J Cataract Refract Surg 1993; 19:713–720. - PubMed