Use of the right internal mammary artery and the great saphenous vein for left anterior descending artery revascularization in patients whose left internal mammal artery cannot be used: a study based on transit-time flow measurement
- PMID: 32503570
- PMCID: PMC7275617
- DOI: 10.1186/s13019-020-01172-5
Use of the right internal mammary artery and the great saphenous vein for left anterior descending artery revascularization in patients whose left internal mammal artery cannot be used: a study based on transit-time flow measurement
Abstract
Background: Owing to the high patency, the use of the left internal mammary artery (LIMA) for left anterior descending artery (LAD) grafting has been a cornerstone of coronary artery bypass grafting surgery (CABG). However, for some patients whose LIMA cannot be used, surgeons have to choose other conduit materials to revascularize the LAD. The purpose of this study was to explore the differences in different conduit materials used for LAD in terms of parameters measured by transit-time flow measurement (TTFM) and the early graft patency detected by computed tomography angiography.
Methods: We retrospectively collected the data of 410 patients who underwent isolated primary OPCAB with intraoperative TTFM data. According to the strategy of the LAD revascularization, 410 patients were assigned to three groups: a left internal mammal artery (LIMA) group (n = 333), a right IMA (RIMA) group (n = 34) and a great saphenous vein (SVG) group (n = 43). The baseline and perioperative blood parameters were compared for the three groups, as well as the early graft patency rates.
Results: Compared with the LIMA-LAD group, the SVG-LAD group had a significantly higher mean graft flow volume (MGF) (37.15 ± 23.29 vs 29.71 ± 20.94 ml/min, P = 0.036), however, had a lower value of pulse index (PI) (2.07 ± 0.62 vs 2.65 ± 1.01, P<0.001). There was no significant difference between the two groups in terms of DF (P>0.05). Compared with the RIMA-LAD group, the SVG-LAD group just had a lower value of PI (2.07 ± 0.62 vs 2.56 ± 0.96, P = 0.029). However, there was no significant difference between the two groups in terms of MGF and DF (P>0.05). Compared with the LIMA-LAD group, the RIMA-LAD group had a slightly lower value of DF (70.76 ± 11.87 vs 74.06 ± 7.09, P = 0.018), while there was no difference in terms of MGF and PI between the two groups (P>0.05). The patency rate of the LIMA-LAD group was 98.72% (309/313), that of RIMA-LAD group was 97.06% (33/34), and that of SVG-LAD group was 100%. There was no difference among the three groups in patency rate (P = 0.405).
Conclusions: SVG-LAD has a higher intraoperative MGF and a lower value of the PI than both LIMA-LAD and RIMA-LAD. RIMA has a higher preoperative blood flow and a lower value of the PI than LIMA; however, there were no significant difference between RIMA grafted to LAD and LIMA grafted to LAD in terms of MGF, PI and DF. In situ skeletonized RIMA did not increase blood flow compared to pedicled LIMA.
Keywords: Great saphenous vein; Internal mammal artery; Left descending artery; Transit-time flow measurement.
Conflict of interest statement
The authors declare that they have no competing interests.
Figures
Similar articles
-
Mid-term graft patency of right versus left internal mammary artery as arterial conduit usage for left anterior descending artery revascularisation: Insights from a single-centre study of propensity-matched data.Int J Surg. 2017 Dec;48:99-104. doi: 10.1016/j.ijsu.2017.10.037. Epub 2017 Oct 20. Int J Surg. 2017. PMID: 29061389
-
Application of bilateral internal mammary artery with different configurations in coronary artery bypass grafting.J Cardiothorac Surg. 2021 Jan 6;16(1):2. doi: 10.1186/s13019-020-01380-z. J Cardiothorac Surg. 2021. PMID: 33407683 Free PMC article.
-
Graft flow evaluation with intraoperative transit-time flow measurement in off-pump versus on-pump coronary artery bypass grafting.JTCVS Tech. 2022 May 17;15:95-106. doi: 10.1016/j.xjtc.2022.05.002. eCollection 2022 Oct. JTCVS Tech. 2022. PMID: 36276694 Free PMC article.
-
Treatment of Complex Two-Vessel Coronary Heart Disease with Single Left Internal Mammary Artery as T-Graft with Itself-A Retrospective Double Center Analysis of Short-Term Outcomes.Medicina (Kaunas). 2022 Oct 9;58(10):1415. doi: 10.3390/medicina58101415. Medicina (Kaunas). 2022. PMID: 36295575 Free PMC article. Review.
-
Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review.Eur J Cardiothorac Surg. 2017 Jan;51(1):26-33. doi: 10.1093/ejcts/ezw203. Epub 2016 Jun 13. Eur J Cardiothorac Surg. 2017. PMID: 27298393 Review.
Cited by
-
Personalized surgical planning for coronary bypass graft configurations using patient-specific computational modeling to avoid flow competition in arterial grafts.Front Cardiovasc Med. 2023 Feb 2;10:1095678. doi: 10.3389/fcvm.2023.1095678. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 36815022 Free PMC article.
-
A predictive patient-specific computational model of coronary artery bypass grafts for potential use by cardiac surgeons to guide selection of graft configurations.Front Cardiovasc Med. 2022 Sep 27;9:953109. doi: 10.3389/fcvm.2022.953109. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36237904 Free PMC article.
-
Use of the In Situ Right Internal Thoracic Artery as an Alternative Single-Inflow Source.Ann Thorac Surg Short Rep. 2023 Apr 14;1(3):396-400. doi: 10.1016/j.atssr.2023.04.001. eCollection 2023 Sep. Ann Thorac Surg Short Rep. 2023. PMID: 39790961 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous