Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-Analysis
- PMID: 32510020
- PMCID: PMC7265264
- DOI: 10.1016/j.joco.2019.01.010
Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-Analysis
Abstract
Purpose: To review the published data about changes in the anterior chamber depth (ACD) in keratoconus patients.
Methods: In this systematic review and meta-analysis of observational studies, we reviewed the available and relevant literature on anterior segment changes in keratoconic eyes, with a special focus on the ACD, an effective factor in many surgical methods. Articles published up to December 2017 were identified in the following data sources: PubMed, Scopus, Ovid, ISI, ScienceDirect, and Google Scholar. Databases were comprehensively searched using the key words "Anterior Chamber Depth AND Anterior segment AND Keratoconus".
Results: A total of 496 studies including these key words were detected. Four hundred fifty-three studies were excluded, and overall 16 studies which precisely described the change in ACD were included in the literature review. The results show that with respect to the applied device, there was a statistically significant difference in ACD between keratoconic eyes and normal eyes except for Galilei analyzer.
Conclusion: Summarizing the results of studies, this review revealed that ACD is significantly deeper in keratoconic eyes as compared with normal eyes, which could be explained by the steeper corneal curvature.
Keywords: Anterior chamber depth; Anterior segment; Keratoconus.
Copyright: © 2020 Journal of Current Ophthalmology.
Conflict of interest statement
There are no conflicts of interest.
Figures
References
-
- Sahebjada S, Xie J, Chan E, Snibson G, Daniel M, Baird PN. Assessment of anterior segment parameters of keratoconus eyes in an Australian population. Optom Vis Sci. 2014;91:803–9. - PubMed
-
- Edmonds CR, Wung SF, Pemberton B, Surrett S. Comparison of anterior chamber depth of normal and keratoconus eyes using scheimpflug photography. Eye Contact Lens. 2009;35:120–2. - PubMed
-
- Abolbashari F, Mohidin N, Ahmadi Hosseini SM, Mohd Ali B, Retnasabapathy S. Anterior segment characteristics of keratoconus eyes in a sample of Asian population. Cont Lens Anterior Eye. 2013;36:191–5. - PubMed
-
- Kovács I, Miháltz K, Németh J, Nagy ZZ. Anterior chamber characteristics of keratoconus assessed by rotating scheimpflug imaging. J Cataract Refract Surg. 2010;36:1101–6. - PubMed
-
- Reddy JC, Rapuano CJ, Cater JR, Suri K, Nagra PK, Hammersmith KM. Comparative evaluation of dual scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes. J Cataract Refract Surg. 2014;40:582–92. - PubMed