. 2020 Oct;41(7):1386-1390.
doi: 10.1007/s00246-020-02380-5. Epub 2020 Jun 10.

Assessing Patent Ductus Arteriosus (PDA) Significance on Cardiac Output by Whole-Body Bio-impedance

Affiliations

Assessing Patent Ductus Arteriosus (PDA) Significance on Cardiac Output by Whole-Body Bio-impedance

Ruth Rafaeli Rabin et al. Pediatr Cardiol. 2020 Oct.

Abstract

We evaluated the effectiveness of a whole-body bioimpedance device (NICaS®, NI Medical, Petach Tikva, Israel) to predict the presence of a hemodynamically significant patent ductus arteriosus (PDA) in premature infants. A total of 36 infants less than 35 week's gestation age and birth weights of less than 1750 g were included in the study. Using the NICaS® device, we obtained whole-body bioimpedance measurements of stroke volume index (SI), cardiac output index (CI) and total peripheral resistance index. A total of 61 measurements were taken together with echocardiograph imaging. The study population was divided into three groups according to the echocardiograph results: group 1-small PDA, group 2-moderate PDA, and group 3-large PDA. Both SI and CI significantly increased from a median value of 22.6 ml/m2 and 3.4 l/min/m2 to 23.8 and 3.7, to 39.8 and 5.4 between groups 1, 2 and 3 respectively. The difference was statistically significant between groups 1 and 3 (P = 0.005 for SI and P = 0.002 for CI) and between groups 2 and 3 (P = 0.037 for SI and P = 0.05 for CI). We found statistically significant differences in SI and CI between infants with large PDAs and infants with no or small and medium PDAs. We suggest that these differences can be used in real time, in addition to echocardiography, in assessing the presence of significant PDAs.

Keywords: Cardiac output index (CI); Patent ductus arteriosus; Preterm infant; Stroke volume index (SI); Total peripheral resistance index (TPRI); Whole-body bioimpedance.

PubMed Disclaimer

References

    1. Benitz WE (2016) Committee on F, Newborn AAoP. Patent ductus arteriosus in preterm infants. Pediatrics 137–143
    1. Heuchan AM, Clyman RI (2014) Managing the patent ductus arteriosus: current treatment options. Arch Dis Child Fetal Neonatal Ed 99:F431–F436 - DOI
    1. Rolland A, Shankar-Aguilera S, Diomande D, Zupan-Simunek V, Boileau P (2015) Natural evolution of patent ductus arteriosus in the extremely preterm infant. Arch Dis Child Fetal Neonatal Ed 100:F55–F58 - DOI
    1. Garland J, Buck R, Weinberg M (1994) Pulmonary hemorrhage risk in infants with a clinically diagnosed patent ductus arteriosus: a retrospective cohort study. Pediatrics 94:719–723
    1. Sehgal A, McNamara PJ (2012) The ductus arteriosus: a refined approach! Semin Perinatol 36:105–113 - DOI