Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan;28(4):3897-3905.
doi: 10.1007/s11356-020-09579-2. Epub 2020 Jun 13.

Removal of fluoride from water by using a coagulant (inorganic polymeric coagulant)

Affiliations

Removal of fluoride from water by using a coagulant (inorganic polymeric coagulant)

Yogendra Singh Solanki et al. Environ Sci Pollut Res Int. 2021 Jan.

Abstract

Excess fluoride (F) ion of drinking water is a major problem in many areas of India and causes harmful effects such as dental and skeletal fluorosis. The World Health Organization (WHO 2004) recommends an upper limit of 1.5 mg/L fluoride in drinking water, and the concentration of fluoride in groundwater has been found 10-20 times higher in many of the States in India. In this study, the performance of inorganic polymeric coagulant (IPC) named as IPC-23, IPC-13, IPC-17, and alum for fluoride removal from drinking water was investigated. The amount of IPC was decided according to the Al2O3 amount present in the alum dose recommended in the batch Nalgonda defluoridation technique. The effects of coagulant dosage (IPC) at different pH and initial concentrations of fluoride on fluoride removal have been studied. The synthetic sample having a fluoride concentration of 2 to 6 mg/L was treated at the optimized dosage and residual fluoride was reduced to 1.0 to 1.2 ppm with IPC-17. Residual aluminum in treated water was well within WHO norms (< 200 μg/L) for drinking water. Optimum pH for fluoride removal was 6.5, and there was deterioration in the performance of IPC at both lower and higher pH.

Keywords: Coagulation; De-fluoridation; Fluoride; IPC; Nalgonda.

PubMed Disclaimer

References

    1. Ali S, Thakur SK, Sarkar A, Shekhar S (2016) Worldwide contamination of water by fluoride. Environ Chem Lett 14(3):291–315 - DOI
    1. Allouche L, Taulelle F (2003) Conversion of Al 13 Keggin ε into Al 30 : a reaction controlled by aluminum monomers. Inorg Chem Commun 6(9):1167–1170 - DOI
    1. Arfin T, Waghmare S (2015) Fluoride removal from water by various techniques: review. International Journal of Innovative Science, Engineering & Technology 2:560–571
    1. Bhatnagar A, Kumar E, Sillanpää M (2011) Fluoride removal from water by adsorption-a review. Chem Eng J 171(3):811–840. https://doi.org/10.1016/j.cej.2011.05.028 - DOI
    1. Biswas G, Kumari M, Adhikari K et al. (2017) A critical review on occurrence of fluoride and its removal through adsorption with an emphasis on natural minerals. Curr Pollution Rep 3(2):104–119. https://doi.org/10.1007/s40726-017-0054-8

LinkOut - more resources