Practical Approach to Using Trend Arrows on Real-Time Continuous Glucose Monitoring System in Type 1 Diabetes Adolescents Living Camp Setting Treated With Multiple Daily Injection or Continuous Subcutaneous Insulin Infusion Insulin Therapy
- PMID: 32552001
- PMCID: PMC8442179
- DOI: 10.1177/1932296820934803
Practical Approach to Using Trend Arrows on Real-Time Continuous Glucose Monitoring System in Type 1 Diabetes Adolescents Living Camp Setting Treated With Multiple Daily Injection or Continuous Subcutaneous Insulin Infusion Insulin Therapy
Abstract
Background: The aim of the study was to determine the effect of an educational intervention on the use of trend arrows of a real-time continuous glucose monitoring (rt-CGM) to manage daily therapy decisions in a group of adolescents with type 1 diabetes attending a camp. The secondary aim was to evaluate the variations in total daily dose (TDD) of insulin requirement.
Methods: Twenty patients (15-17 years) on multiple insulin injections (n = 8) or continuous subcutaneous insulin infusion (n = 12) attended a training session at the beginning of the camp to learn our algorithm for the management of therapy depending on trend arrows. TDD, time in range (TIR), time above range (TAR), and time below range (TBR) (in the 24 hours and in the three hours after breakfast) before the training session (run-in) and at the end of the camp (T1) were analyzed.
Results: Data showed a reduction of TAR (run-in 42.6%, T1 32.05%, P = .036) and an increase in TIR (run-in 52.9%, T1 62.4%, P = .013). Reduction of TBR (run-in 42.5%, T1 37.5%, P = .05) and improvement in TIR (run-in 49.0%, T1 57.0%, P = .02) were also observed in the post-breakfast period. Data showed a significant reduction in the TDD (run-in 52.02 ± 17.44 U/die, T1 46.49 ± 12.39 U/die, P = .024).
Conclusions: Statistically significant improvement of glycemic control and reduction of TTD were observed in all patients regardless of therapy type. The improvement between run-in and T1 demonstrates the importance of patients' education on the correct use of rt-CGM with simple algorithms for the management of therapy.
Keywords: fine-tuning; insulin dose adjustments; real-time continuous glucose monitoring; trend arrows; type 1 diabetes.
Conflict of interest statement
Figures
Similar articles
-
Individualization of recommendations from the international consensus on continuous glucose monitoring-derived metrics in Japanese children and adolescents with type 1 diabetes.Endocr J. 2020 Oct 28;67(10):1055-1062. doi: 10.1507/endocrj.EJ20-0193. Epub 2020 Jun 20. Endocr J. 2020. PMID: 32565500
-
Glucose Variability and Time in Range in Type 2 Diabetes Treated with U-500R by Pump or Injection: CGM Findings from the VIVID Study.Diabetes Technol Ther. 2021 Jan;23(1):51-58. doi: 10.1089/dia.2020.0030. Epub 2020 Sep 18. Diabetes Technol Ther. 2021. PMID: 32631081
-
Combined continuous glucose monitoring and subcutaneous insulin infusion versus self-monitoring of blood glucose with optimized multiple injections in people with type 1 diabetes: A randomized crossover trial.Diabetes Obes Metab. 2020 Aug;22(8):1286-1291. doi: 10.1111/dom.14028. Epub 2020 Apr 8. Diabetes Obes Metab. 2020. PMID: 32166907 Clinical Trial.
-
Optimizing type 1 diabetes after multiple daily injections and capillary blood monitoring: Pump or sensor first? A meta-analysis using pooled differences in outcome measures.Diabetes Obes Metab. 2021 Nov;23(11):2521-2528. doi: 10.1111/dom.14498. Epub 2021 Aug 12. Diabetes Obes Metab. 2021. PMID: 34286892
-
Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035. Diabetes Technol Ther. 2017. PMID: 28585879 Free PMC article. Review.
Cited by
-
Clinical Evaluation of a Novel CGM-Informed Bolus Calculator with Automatic Glucose Trend Adjustment.Diabetes Technol Ther. 2022 Jan;24(1):18-25. doi: 10.1089/dia.2021.0140. Epub 2021 Sep 3. Diabetes Technol Ther. 2022. PMID: 34491825 Free PMC article.
-
Fear of Hypoglycemia and Diabetes Distress: Expected Reduction by Glucose Prediction.J Diabetes Sci Technol. 2024 Sep;18(5):1027-1034. doi: 10.1177/19322968241267886. Epub 2024 Aug 19. J Diabetes Sci Technol. 2024. PMID: 39158974 Free PMC article.
-
Using Continuous Glucose Monitoring Values for Bolus Size Calculation in Smart Multiple Daily Injection Systems: No Negative Impact on Post-bolus Glycemic Outcomes Found in Real-World Data.J Diabetes Sci Technol. 2025 May;19(3):642-648. doi: 10.1177/19322968231202803. Epub 2023 Sep 24. J Diabetes Sci Technol. 2025. PMID: 37743727 Free PMC article.
-
Type 1 Diabetes and Addison's Disease: When the Diagnosis Is Suggested by the Continuous Glucose Monitoring System.Children (Basel). 2021 Aug 14;8(8):702. doi: 10.3390/children8080702. Children (Basel). 2021. PMID: 34438593 Free PMC article.
-
Use of continuous glucose monitoring trend arrows in the younger population with type 1 diabetes.Diab Vasc Dis Res. 2021 Nov-Dec;18(6):14791641211062155. doi: 10.1177/14791641211062155. Diab Vasc Dis Res. 2021. PMID: 34898300 Free PMC article. Review.
References
-
- Szypowska A, Ramotowska A, Dzygalo K, Golicki D.Beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials. Eur J Endocrinol. 2012;166(4):567-574. - PubMed
-
- Bergenstal RM, Tamborlane WV, Ahmann A, et al.. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010;363(4):311-320. - PubMed
-
- Slover RH, II. Continuous glucose monitoring in children and adolescents. Curr Diab Rep. 2012;12(5):510-516. - PubMed
-
- Kordonouri O, Pankowska E, Rami B, et al.. Sensor-augmented pump therapy from the diagnosis of childhood type 1 diabetes: results of the Paediatric Onset Study (ONSET) after 12 months of treatment. Diabetologia. 2010;53(12):2487-2495. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials