Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 May-Jun:259-260:105472.
doi: 10.1016/j.tvjl.2020.105472. Epub 2020 May 18.

Salivary D-dimer in pigs: Validation of an automated assay and changes after acute stress

Affiliations

Salivary D-dimer in pigs: Validation of an automated assay and changes after acute stress

M J López-Martínez et al. Vet J. 2020 May-Jun.

Abstract

D-dimer is a peptide found in serum and is derived from the degradation of blood clots. Even though it has been analysed in human saliva, D-dimer has not been previously evaluated in the saliva of any veterinary species, and its source and role remain unknown. The objectives of this research were firstly, to validate the use of an automated method for the measurement of D-dimer in porcine saliva, and secondly, to evaluate whether D-dimer concentration changes in pig saliva after an acute stress stimulus. For this purpose, a complete analytical validation of a commercially-available immunoturbidimetric assay was carried out. In addition, an experimental acute stress model was induced in 11 pigs based on a technique involving restraint by nose-snare immobilisation for 1 min. Saliva samples were subsequently collected at different times and D-dimer, salivary alpha-amylase (sAA) and cortisol were assessed in order to evaluate changes in its concentrations after the stress induction. The D-dimer automated assay showed adequate reproducibility and sensitivity, with coefficients of variation below 10% and a limit of quantification of 0.167 μg/mL fibrinogen equivalent units (FEU). It also showed a high accuracy, determined by linearity under dilution and recovery tests. In the stress model, a significant increase (P < 0.05) in salivary D-dimer 15 min after the stress stimulus and a positive correlation between D-dimer and sAA (r = 0.51; P < 0.001) were observed. These results indicate that D-dimer can be measured in porcine saliva with an automated method and suggest that its concentration can be influenced by stressful conditions.

Keywords: Alpha-amylase; Cortisol; D-dimer; Saliva; Stress; Swine.

PubMed Disclaimer

Publication types

LinkOut - more resources