Comparison of Two Specialized Histology Needles for Endoscopic Ultrasound (EUS)-Guided Liver Biopsy: A Pilot Study

Affiliations
Observational Study

Comparison of Two Specialized Histology Needles for Endoscopic Ultrasound (EUS)-Guided Liver Biopsy: A Pilot Study

Rintaro Hashimoto et al. Dig Dis Sci. 2021 May.

Abstract

Background: EUS-guided liver biopsy (EUS-LB) has been shown to be a safe and effective alternative to percutaneous liver biopsy. The optimal needle device and technique for EUS-LB is still evolving. The aim of this study was to compare the efficacy of two second-generation 19G fine-needle biopsy (FNB) (Franseen- and Fork-tip) devices for EUS-LB.

Methods: This is a repeated-measure crossover study with a prospectively maintained cohort of patients. We performed EUS-LB with a one-pass and single-actuation method using two 19G FNB needles in 22 consecutive patients between 10/2018 and 9/2019. Patients were randomized to left vs right liver lobes to be biopsied as well as the needle sequence. The specimens obtained were evaluated for adequacy for histologic diagnosis. The primary outcome was number of complete portal tracts (CPTs), post-fix aggregate, and longest specimen length. Secondary outcomes were prefix aggregate specimen length and the specimen adequacy judged by two expert pathologists.

Results: A total of 44 liver biopsies were performed in 22 patients. The CPTs were higher in the Franseen-tip needle group compared to the Fork-tip needle group (14.4 vs 9.5, p = 0.043). Post-fix aggregate specimen length (44.9 mm vs 34.6 mm, p = 0.097), the post-fix longest specimen length (19.9 mm vs 13.7 mm, p = 0.175), and prefix aggregate specimen length (51.7 mm vs 45 mm, p = 0.265) were not significantly different. Both needles showed similarly high histologic adequacy (100% vs 95.5%, p = 0.312). Interestingly, the right of the liver showed higher yield of CPTs with both needles (Franseen, 16.2 vs. 12.8, p = 0.003, the Fork-tip, 12.8 vs. 7.0, p < 0.0001).

Conclusion: EUS-guided liver biopsy using the 19G Franseen-tip needle may provide more CPTs than 19G Fork-tip needle on a single-pass, single-actuation comparison.

Keywords: Endoscopic ultrasound-guided fine-needle aspiration; Endosonography; Liver biopsy; Observational study.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mathew A. EUS-guided routine liver biopsy in selected patients. Am J Gastroenterol. 2007;102:2354–2355. - DOI
    1. Gleeson FC, Clayton AC, Zhang L, et al. Adequacy of endoscopic ultrasound core needle biopsy specimen of nonmalignant hepatic parenchymal disease. Clin Gastroenterol Hepatol. 2008;6:1437–1440. - DOI
    1. Dewitt J, McGreevy K, Cummings O, et al. Initial experience with EUS-guided Tru-cut biopsy of benign liver disease. Gastrointest Endosc. 2009;69:535–542. - DOI
    1. Stavropoulos SN, Im GY, Jlayer Z, et al. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012;75:310–318. - DOI
    1. Nakai Y, Samarasena JB, Iwashita T, et al. Autoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle. Endoscopy. 2012;44:E67–E68. - DOI

Publication types

LinkOut - more resources