Color determination with no-match-templates using two different tooth color scales-An in vitro evaluation
- PMID: 32562469
- DOI: 10.1111/jerd.12594
Color determination with no-match-templates using two different tooth color scales-An in vitro evaluation
Abstract
Objectives: Visual shade selection is the most commonly used method in dentistry and a challenge for every dentist. However, differences to natural tooth color and the differences of each shade guide are well known. The aim of this paper is to investigate the suitability of two different color scales for determining the color of no-match templates.
Materials and methods: Volunteers (N = 76) selected a shade color of a no-match template with two shade guides (VITA Classical shade guide (VC) and VITA Linearguide 3D-Master (V3D LG), both Vita Zahnfabrik). The neutral grey background was laterally illuminated with a color differentiation lamp (Dialite, Eickhorst GmbH). For the volunteers' accuracy, the triangle's area was used which are emerge by the color coordinates of a template (LT aT bT ) and the color coordinates of the two decisions (L1 a1 b1 and L2 a2 b2 ). Statistical software was used to evaluate the differences in ΔE00 with α = .01.
Results: A deviation in the median of ΔE00 of 7.6 (V3D LG, first choice) to 6.6 (VC, second choice) was detected, while U test showed no significant differences in the median for both color scales. But the triangle's area generated by both shade decisions and tooth color with V3D LG was significant smaller (14.2) then VC (19.2) (P ≤ .001).
Conclusions: When comparing both results no significant difference in the subject's shade selection and the shade guides was detected. The new evaluation strategy using the size of the triangle's areas proves the superiority of the V3D LG due to a better distribution of the tooth color shades within the color space.
Keywords: color space differences; no-matched templates; shade taking; tooth color.
© 2020 The Authors. Journal of Esthetic and Restorative Dentistry published by Wiley Periodicals LLC.
References
REFERENCES
-
- Lehmann KM, Igiel C, Schmidtmann I, Scheller H. Four color-measuring devices compared with a spectrophotometric reference system. J Dent. 2010;38(Suppl 2):e65-e70.
-
- Oomen JA, Slager CJ, Lehmann KG, Schuurbiers JC, Serruys PW. Color quantification in angioscopic video images. Med Prog Technol. 1995;21(1):39-46.
-
- Schwabacher WB, Goodkind RJ. Three-dimensional color coordinates of natural teeth compared with three shade guides. J Prosthet Dent. 1990;64(4):425-431.
-
- Stokes M, Fairchild MD, Berns RS. Colorimetric quantified visual tolerances for pictorial images. Comparison of color images presented in different media. In: Pearson M, (ed.), Comparison of color images presented in different media. Vol 2. Warrendale, Pennsylvania: Tech. Assoc. Graphic Arts and Inter-Soc. Color Council (TAGA); 1992;757-777.
-
- Tung FF, Goldstein GR, Jang S, Hittelman E. The repeatability of an intraoral dental colorimeter. J Prosthet Dent. 2002;88(6):585-590.
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources