. 2020 Aug;52(8):687-700.
doi: 10.1055/a-1185-3109. Epub 2020 Jun 22.

Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2020

Affiliations
Free article

Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2020

Cesare Hassan et al. Endoscopy. 2020 Aug.
Free article

Abstract

The following recommendations for post-polypectomy colonoscopic surveillance apply to all patients who had one or more polyps that were completely removed during a high quality baseline colonoscopy. 1: ESGE recommends that patients with complete removal of 1 - 4 < 10 mm adenomas with low grade dysplasia, irrespective of villous components, or any serrated polyp < 10 mm without dysplasia, do not require endoscopic surveillance and should be returned to screening.Strong recommendation, moderate quality evidence.If organized screening is not available, repetition of colonoscopy 10 years after the index procedure is recommended.Strong recommendation, moderate quality evidence. 2: ESGE recommends surveillance colonoscopy after 3 years for patients with complete removal of at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia. Strong recommendation, moderate quality evidence. 3: ESGE recommends a 3 - 6-month early repeat colonoscopy following piecemeal endoscopic resection of polyps ≥ 20 mm.Strong recommendation, moderate quality evidence. A first surveillance colonoscopy 12 months after the repeat colonoscopy is recommended to detect late recurrence.Strong recommendation, high quality evidence. 4: If no polyps requiring surveillance are detected at the first surveillance colonoscopy, ESGE suggests to perform a second surveillance colonoscopy after 5 years. Weak recommendation, low quality evidence.After that, if no polyps requiring surveillance are detected, patients can be returned to screening. 5: ESGE suggests that, if polyps requiring surveillance are detected at first or subsequent surveillance examinations, surveillance colonoscopy may be performed at 3 years. Weak recommendation, low quality evidence.A flowchart showing the recommended surveillance intervals is provided (Fig. 1).

PubMed Disclaimer

Conflict of interest statement

M. Bretthauer’s department has received support and cooperation from the EndoBRAIN study from Olympus Europa SE (from 2019 ongoing). E. Dekker has received consultancy honoraria from Fujifilm, Olympus, Tillots, GI Supply, and CPP-FAP, and speakers’ fees from Olympus, Roche and GI Supply; she has endoscopic equipment on loan and receives a research grant from Fujifilm. L.M. Helsingen’s department has received support and cooperation from the EndoBRAIN study from Olympus Europa SE (from 2019 ongoing). J.E. van Hooft has received lecture fees from Medtronics (from 2014 to 2015 and 2019) and Cook Medical (2019), and consultancy fees from Boston Scientific (2014 – 2017); her department has received research grants from Cook Medical (2014 – 2019) and Abbott (2014 – 2017). M. Pellisé has received consultancy and speaker’s fees from Norgine Iberia (2015 – 2019), a consultancy fee from GI Supply (2019), speaker’s fees from Casen Recordati (2016 – 2019), Olympus (2018), and Jansen (2018), and research funding from Fujifilm Spain (2019), Fujifilm Europe (2020), and Casen Recordati (2020); her department has received loan material from Fujifilm Spain (from 2017 ongoing), a research grant from Olympus Europe (2005 – 2019), and loan material and a research grant from Fujifilm Europe (2020 – 2021); she is a Board member of ESGE and SEED; and receives a fee from Thieme as an Endoscopy Co-Editor. J. Regula has received sponsorship and lecture fees from Ipsen Pharma and Alfasigma (2017 – 2020). M. Rutter is a member of the British Society of Gastroenterology. G. Antonelli, A. Bleijenberg, S. Chaussade, M. Dinis-Ribeiro, J.-M. Dumonceau, M. Ferlitsch, A. Gimeno-Garcia, C. Hassan, R. Jover, M. Kalager, C. Pox, E. Quintero, and L. Ricciardello, and C. Senore have no competing interests.