Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2020 Apr 13:25:35.
doi: 10.4103/jrms.JRMS_21_18. eCollection 2020.

Detailed procedure and clinical application overview of rapid on-site evaluation in diagnostic interventional pulmonology

Affiliations
Review

Detailed procedure and clinical application overview of rapid on-site evaluation in diagnostic interventional pulmonology

Caili Li et al. J Res Med Sci. .

Abstract

Diagnostic interventional pulmonology is widely accepted as a minimally invasive, highly accurate procedure for diagnosing lung cancer, more drug-resistant pathogen infections of lower respiratory tract, and critical respiratory diseases. The efficiency of interventional diagnostics depends on quite a few factors, including size and the anatomic location of lymph nodes, number of biopsy sites and complications rate, characteristics of the lesion, and underlying disease. Specifically, the application of rapid on-site evaluation (ROSE) may avoid additional sampling without compromising diagnostic yield with a preliminary evaluation for adequate diagnostic material and thus reduce the complication rate. In this review article we aimed at elaborate the technical details, clinical roles, and technological progress of ROSE in diagnostic interventional pulmonology, highlighting the importance of ROSE in diagnostic interventional pulmonology. We finally pointed out that it will be a tendency for a pulmonologist, to undergo a short yet intensive training and perform ROSE in diagnostic interventional pulmonology.

Keywords: Diagnose; interventional pulmonology; rapid on-site evaluation; sampling.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Similar articles

Cited by

References

    1. Pak HY, Yokota S, Teplitz RL, Shaw SL, Werner JL. Rapid staining techniques employed in fine needle aspirations of the lung. Acta Cytol. 1981;25:178–84. - PubMed
    1. Davenport RD. Rapid on-site evaluation of transbronchial aspirates. Chest. 1990;98:59–61. - PubMed
    1. Eapen GA, Shah AM, Lei X, Jimenez CA, Morice RC, Yarmus L, et al. Complications, consequences, and practice patterns of endobronchial ultrasound-guided transbronchial needle aspiration: Results of the AQuIRE registry. Chest. 2013;143:1044–53. - PMC - PubMed
    1. Gasparini S. It is time for this 'ROSE' to flower. Respiration. 2005;72:129–31. - PubMed
    1. Trisolini R, Cancellieri A, Tinelli C, Paioli D, Scudeller L, Casadei GP, et al. Rapid on-site evaluation of transbronchial aspirates in the diagnosis of hilar and mediastinal adenopathy: A randomized trial. Chest. 2011;139:395–401. - PubMed