Pump-Free Microfluidic Rapid Mixer Combined with a Paper-Based Channel
- PMID: 32583663
- DOI: 10.1021/acssensors.0c00937
Pump-Free Microfluidic Rapid Mixer Combined with a Paper-Based Channel
Abstract
Capillary forces are commonly employed to transport fluids in pump-free microfluidic platforms such as paper-based microfluidics. However, since paper is a porous material consisting of nonuniform cellulose fibers, it has some limitations in performing stable flow functions like mixing. Here, we developed a pump-free microfluidic device that enables rapid mixing by combining paper and plastic. The device was fabricated by laminating transparency film and double-sided adhesive and is composed of an overlapping inlet ending in a paper-based reaction area. The mixing performance of the developed device was confirmed experimentally using aqueous dyes and pH indicators. In addition, the absolute mixing index was evaluated by numerically calculating the concentration field across the microfluidic channels. To demonstrate the utility of the new approach, the detection of an organophosphate pesticide was carried out using a colorimetric enzymatic inhibition assay. The developed device and a smartphone application were used to detect organophosphate pesticide on food samples, demonstrating the potential for onsite analysis.
Keywords: capillary-driven microfluidic; colorimetric enzymatic inhibition assay; onsite analysis; passive mixer; pesticide.
Similar articles
-
Evaluation of cellophane as platform for colorimetric assays on microfluidic analytical devices.Mikrochim Acta. 2023 Jan 9;190(2):48. doi: 10.1007/s00604-022-05622-w. Mikrochim Acta. 2023. PMID: 36622479
-
Smartphone-coupled three-layered paper-based microfluidic chips demonstrating stereoscopic capillary-driven fluid transport towards colorimetric detection of pesticides.Anal Bioanal Chem. 2022 Feb;414(5):1759-1772. doi: 10.1007/s00216-021-03839-x. Epub 2022 Jan 21. Anal Bioanal Chem. 2022. PMID: 35059790
-
A hybrid paper and microfluidic chip with electrowetting valves and colorimetric detection.Analyst. 2014 Jun 21;139(12):3002-8. doi: 10.1039/c3an01516e. Analyst. 2014. PMID: 24719901
-
Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review.Anal Chim Acta. 2017 Jun 1;970:1-22. doi: 10.1016/j.aca.2017.03.037. Epub 2017 Mar 27. Anal Chim Acta. 2017. PMID: 28433054 Review.
-
Recent developments in flow modeling and fluid control for paper-based microfluidic biosensors.Biosens Bioelectron. 2021 Apr 15;178:113026. doi: 10.1016/j.bios.2021.113026. Epub 2021 Jan 23. Biosens Bioelectron. 2021. PMID: 33545552 Review.
Cited by
-
Ultrasensitive detection of acephate based on carbon quantum dot-mediated fluorescence inner filter effects.Analyst. 2022 Nov 21;147(23):5462-5469. doi: 10.1039/d2an01552h. Analyst. 2022. PMID: 36318045 Free PMC article.
-
Paper-Based Vertical Flow Assays for in Vitro Diagnostics and Environmental Monitoring.ACS Sens. 2025 May 23;10(5):3317-3339. doi: 10.1021/acssensors.5c00668. Epub 2025 May 15. ACS Sens. 2025. PMID: 40372939 Free PMC article. Review.
-
Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics.Anal Chim Acta. 2023 Oct 9;1277:341634. doi: 10.1016/j.aca.2023.341634. Epub 2023 Jul 27. Anal Chim Acta. 2023. PMID: 37604607 Free PMC article.
-
Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2.ACS Meas Sci Au. 2022 Dec 21;2(6):584-594. doi: 10.1021/acsmeasuresciau.2c00037. Epub 2022 Aug 30. ACS Meas Sci Au. 2022. PMID: 36570470 Free PMC article.
-
Capillary driven microfluidic sequential flow device for point-of-need ELISA: COVID-19 serology testing.Anal Methods. 2023 Jun 8;15(22):2721-2728. doi: 10.1039/d3ay00225j. Anal Methods. 2023. PMID: 37099406 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources