Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement: A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man
- PMID: 32604382
- DOI: 10.2106/JBJS.19.01242
Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement: A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man
Abstract
Background: Total hip replacement (THR) with a cemented polished taper-slip (PTS) femoral stem has excellent long-term results but is associated with a higher postoperative periprosthetic femoral fracture (PFF) risk compared with composite beam stems. This study aimed to identify risk factors associated with PFF revision following THR with PTS stems.
Methods: In a retrospective cohort study, 299,019 primary THRs using PTS stems from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) were included, with a median follow-up of 5.2 years (interquartile range [IQR], 3.1 to 8.2 years). The adjusted hazard ratio (HR) of PFF revision was estimated for each variable using multivariable Cox survival regression analysis.
Results: Of 299,019 THR cases, 1,055 underwent revision for PFF at a median time of 3.1 years (IQR, 1.0 to 6.1 years). The mean age (and standard deviation) was 72 ± 9.7 years, 64.3% (192,365 patients) were female, and 82.6% (247,126 patients) had an American Society of Anesthesiologists (ASA) class of 1 or 2. Variables associated with increased PFF were increasing age (HR, 1.02 per year), intraoperative fracture (HR, 2.57 [95% confidence interval (CI), 1.42 to 4.66]), ovaloid (HR, 1.96 [95% CI, 1.22 to 3.16]) and round cross-sectional shapes (HR, 9.58 [95% CI, 2.29 to 40.12]), increasing stem offset (HR, 1.07 per millimeter), increasing head size (HR, 1.04 per millimeter), THR performed from 2012 to 2016 (HR, 1.45 [95% CI, 1.18 to 1.78]), cobalt-chromium stem material (HR, 6.7 [95% CI, 3.0 to 15.4]), and cobalt-chromium stems with low-viscosity cement (HR, 22.88 [95% CI, 9.90 to 52.85]). Variables associated with a decreased risk of PFF revision were female sex (HR, 0.52 [95% CI, 0.45 to 0.59]), increasing stem length (HR, 0.97 per millimeter), and a ceramic-on-polyethylene bearing (HR, 0.55 [95% CI, 0.36 to 0.85]).
Conclusions: Increased risk of PFF revision was associated with PTS stems that are short, have high offset, are used with large femoral heads, are made of cobalt-chromium, or have ovaloid or round cross-sectional shapes. Large increases in PFF risk were associated with cobalt-chromium stems used with low-viscosity cement. Further study is required to confirm causation.
Level of evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Comment in
-
Back to the Future…Don't Forget the Cement: Commentary on an article by J.N. Lamb, BSc, MBBS, MRCS, et al.: "Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement. A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man".J Bone Joint Surg Am. 2020 Sep 16;102(18):e107. doi: 10.2106/JBJS.20.01026. J Bone Joint Surg Am. 2020. PMID: 32941244 No abstract available.
References
-
- Abdel MP, Watts CD, Houdek MT, Lewallen DG, Berry DJ. Epidemiology of periprosthetic fracture of the femur in 32,644 primary total hip arthroplasties: a 40-year experience. Bone Joint J. 2016 Apr;98-B(4):461-7.
-
- Pivec R, Issa K, Kapadia BH, Cherian JJ, Maheshwari AV, Bonutti PM, Mont MA. Incidence and future projections of periprosthetic femoral fracture following primary total hip arthroplasty: an analysis of international registry data. J Long Term Eff Med Implants. 2015;25(4):269-75.
-
- Gitajn IL, Heng M, Weaver MJ, Casemyr N, May C, Vrahas MS, Harris MB. Mortality following surgical management of Vancouver B periprosthetic fractures. J Orthop Trauma. 2017 Jan;31(1):9-14.
-
- Bhattacharyya T, Chang D, Meigs JB, Estok DM 2nd, Malchau H. Mortality after periprosthetic fracture of the femur. J Bone Joint Surg Am. 2007 Dec;89(12):2658-62.
-
- Thien TM, Chatziagorou G, Garellick G, Furnes O, Havelin LI, Mäkelä K, Overgaard S, Pedersen A, Eskelinen A, Pulkkinen P, Kärrholm J. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the Nordic Arthroplasty Register Association database. J Bone Joint Surg Am. 2014 Oct 1;96(19):e167.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
