Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta
- PMID: 32624310
- DOI: 10.1016/j.jtcvs.2020.05.031
Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta
Erratum in
-
Notice of Correction.J Thorac Cardiovasc Surg. 2022 Aug;164(2):613. doi: 10.1016/j.jtcvs.2022.06.001. Epub 2022 Jun 9. J Thorac Cardiovasc Surg. 2022. PMID: 35691710 No abstract available.
Abstract
Objectives: To evaluate aortic distensibility and pulse waveform patterns associated with the ascending aortic aneurysm, and to analyze the postoperative and mid-term hemodynamic changes induced by prosthetic replacement of the ascending aorta.
Methods: Central blood pressure waves were recorded at the carotid artery level by means of a validated transcutaneous arterial tonometer in 30 patients undergoing prosthetic replacement of ascending aortic aneurysm and in 30 control patients. Measurements were obtained the day before surgery and 5 to 7 days and 16 to 20 months after surgery.
Results: The ascending aortic aneurysm was associated with a less steep slope of early systolic phase of the pressure curve (pulsus tardus) compared with a control group (0.54 ± 0.18 mm Hg/ms vs 0.69 ± 0.26 mm Hg/ms; P = .011). Replacing the ascending aorta with a noncompliant vascular prosthesis steepened the pulse pressure slope during the early systolic phase in the postoperative period (0.77 ± .29 mm Hg/ms), providing values comparable with those of the control group in the mid-term (0.67 ± .20 mm Hg/ms). No change in aortic stiffness was found either postoperatively or in the mid-term after ascending aorta surgical replacement (carotid-femoral pulse wave velocity: preoperative, 9.0 ± 2.6 m/s; postoperative, 9.0 ± 2.9 m/s; mid-term postoperative, 9.3 ± 2.8 m/s).
Conclusions: This study does not confirm the assumption that substitution of the viscoelastic ascending aorta with a rigid prosthesis can cause serious hemodynamic alterations downstream, because we did not observe a worsening of global aortic distensibility after insertion of a rigid prosthetic aorta. The ascending aortic aneurysm is associated with a pulsus tardus.
Keywords: aortic distensibility; arterial stiffness; ascending aortic aneurysm; pulse wave velocity; thoracic aortic surgery; vascular prosthesis.
Copyright © 2020 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Comment in
-
Commentary: Aortic function: It's more than just a tube.J Thorac Cardiovasc Surg. 2022 Apr;163(4):1293. doi: 10.1016/j.jtcvs.2020.05.114. Epub 2020 Jun 26. J Thorac Cardiovasc Surg. 2022. PMID: 32690410 No abstract available.
-
Commentary: Increased Windkessel effect is a sign of aortic aneurysm.J Thorac Cardiovasc Surg. 2022 Apr;163(4):1294-1295. doi: 10.1016/j.jtcvs.2020.05.113. Epub 2020 Jun 26. J Thorac Cardiovasc Surg. 2022. PMID: 32763036 No abstract available.