Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Aug:226:222-231.
doi: 10.1016/j.ahj.2019.10.015. Epub 2019 Nov 11.

Transcatheter InterAtrial Shunt Device for the treatment of heart failure: Rationale and design of the pivotal randomized trial to REDUCE Elevated Left Atrial Pressure in Patients with Heart Failure II (REDUCE LAP-HF II)

Affiliations

Transcatheter InterAtrial Shunt Device for the treatment of heart failure: Rationale and design of the pivotal randomized trial to REDUCE Elevated Left Atrial Pressure in Patients with Heart Failure II (REDUCE LAP-HF II)

Natalia Berry et al. Am Heart J. 2020 Aug.

Abstract

Background: A randomized, sham-controlled trial in patients with heart failure (HF) and left ventricular ejection fraction (LVEF) ≥40% demonstrated reductions in pulmonary capillary wedge pressure (PCWP) with a novel transcatheter InterAtrial Shunt Device (IASD). Whether this hemodynamic effect will translate to an improvement in cardiovascular outcomes and symptoms requires additional study.

Study design and objectives: REDUCE Elevated Left Atrial Pressure in Patients with Heart Failure II (REDUCE LAP HF-II) is a multicenter, prospective, randomized, sham-controlled, blinded trial designed to evaluate the clinical efficacy of the IASD in symptomatic HF and elevated left atrial pressures. Up to 608 HF patients age ≥ 40 years with LVEF ≥40%, PCWP ≥25 mm Hg during supine ergometer exercise, and PCWP ≥5 mm Hg higher than right atrial pressure will be randomized 1:1 to the IASD versus sham control. Key exclusion criteria include hemodynamically significant valvular disease, evidence of pulmonary arterial hypertension, and right heart dysfunction. The primary endpoint is a hierarchical composite, analyzed by the Finkelstein-Schoenfeld methodology, that includes (1) cardiovascular mortality or first nonfatal ischemic stroke through 12 months; (2) total (first plus recurrent) HF hospitalizations or healthcare facility visits for intravenous diuretics up to 24 months, analyzed when the last randomized patient completes 12 months of follow-up; and (3) change in Kansas City Cardiomyopathy Questionnaire overall summary score from baseline to 12 months. Follow-up echocardiography will be performed at 6, 12, and 24 months to evaluate shunt flow and cardiac chamber size/function. Patients will be followed for a total of 5 years after the index procedure.

Conclusions: REDUCE LAP-HF II is designed to evaluate the clinical efficacy of the IASD device in patients with symptomatic HF with elevated left atrial pressure and LVEF ≥40%.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources