Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Oct;208(4):504-11.
doi: 10.1097/00000658-198810000-00012.

Manipulation of ascitic fluid pressure in cirrhotics to optimize hemodynamic and renal function

Affiliations

Manipulation of ascitic fluid pressure in cirrhotics to optimize hemodynamic and renal function

J A Savino et al. Ann Surg. 1988 Oct.

Abstract

Intra-abdominal pressure (IAP), measured via a transurethral catheter, hemodynamic, and renal functions were evaluated in 25 cirrhotic patients admitted to ICU with variceal bleeding, tense ascites, and peripheral edema. In patients with an IAP greater than 25 cm H2O, a paracentesis was performed to decrease the IAP by 10 cm H2O. After paracentesis, a decrease in the IAP from 33.47 to 19.06 cm H2O (p less than 0.001) resulted in a decrease in total peripheral resistance (TPR) (p less than 0.01) and a significant increase in cardiac index (CI) (p less than 0.001), stroke index (p less than 0.001), left ventricular stroke work (LVSW) (p less than 0.01), and right ventricular stroke work (p less than 0.01). The therapeutic effects of paracentesis on renal function were: a decrease in BUN and serum creatinine (p less than 0.001) and an increase in the creatinine clearance (Ccr) (p less than 0.001), urine volume (p less than 0.001), osmolar clearance (Cosm) (p less than 0.001), and urine creatinine (p less than 0.001) values. The IAP correlated directly with the TPR (r = +0.35, p less than 0.01) and inversely with the CI (r = -0.39, p less than 0.001) and LVSW (r = -0.37, p less than 0.001) in the 126 studies of IAP performed with the 25 patients. IAP also correlated directly with BUN (r = 0.40, p less than 0.001), serum creatinine (r = 0.28, p less than 0.01), and free water clearance (CH2O) (r = 0.3, p less than 0.001); IAP correlated negatively with Ccr (r = -0.54, p less than 0.001) and Cosm (r = -0.43, p less than 0.001). In critically ill cirrhotic patients, IAP, when measured noninvasively via a bladder catheter, is an accurate and useful method to follow manipulation of ascitic fluid pressure quantitatively in order to optimize hemodynamic and renal function.

PubMed Disclaimer

References

    1. Surgery. 1966 Jun;59(6):1135-46 - PubMed
    1. Surgery. 1964 Jul;56:57-74 - PubMed
    1. JAMA. 1968 Jul 1;205(1):120-1 - PubMed
    1. Ann Surg. 1973 Mar;177(3):253-8 - PubMed
    1. Am J Med. 1975 Aug;59(2):165-70 - PubMed

MeSH terms