Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Aug;35(8):1885-1890.
doi: 10.1111/jocs.14821. Epub 2020 Jul 9.

Lost in circulation

Affiliations

Lost in circulation

Hristo Kirov et al. J Card Surg. 2020 Aug.

Abstract

Background: Device complications in complex percutaneous coronary interventions are rare but potentially deadly. Surgical removal is often required. However, an evaluation of surgical therapy beyond case reports is practically not existent.

Methods: We prospectively followed all cases of retained guide wires and/or other devices referred to us for surgical removal between 2015 and 2019 and retrospectively searched our database for such cases between 2010 and 2014.

Results: From 2015 on, eight cases were referred for surgical removal from six different cardiology departments. In the 5 years before, there was not a single case. Six patients were operated emergently. Patients were 60.5 ± 5.42 years old, overweight (body mass index 30.1 ± 3.77) and except for one case (left ventricular-assist device) showed preserved ejection fraction (EF) (mean EF 57 ± 18.01). The retained devices were mostly located in the right coronary artery (50%), followed by the circumflex artery (37.5%) and diagonal branch (12.5%). The devices were remnants of guide wires (n = 4), balloon catheters (n = 3), and in one case a rotablator. Full sternotomy was performed in six patients and two received a left-sided minithoracotomy (n = 2). The operations were performed on-pump in five (62.5%) and off-pump in three patients. Complete extraction of the foreign bodies was possible in all patients. Two patients died; one in unrelated multiorgan failure and one due to retained-device-related right heart failure. The other patients survived and had uneventful postoperative courses.

Conclusions: Retained foreign bodies from cardiac interventions can be completely removed surgically using individualized approaches. There appears to be a trend toward a rising incidence of such interventional complications.

Keywords: coronary intervention; guide wires; surgery.

PubMed Disclaimer

References

REFERENCES

    1. Tomberli B, Mattesini A, Baldereschi GI, Di Mario C. A brief history of coronary artery stents. Rev Esp Cardiol (Engl Ed). 2018;71(5):312-319.
    1. Venkitachalam L, Kip KE, Selzer F, et al. Twenty-year evolution of percutaneous coronary intervention and its impact on clinical outcomes: a report from the National Heart, Lung, and Blood Institute-sponsored, multicenter 1985-1986 PTCA and 1997-2006 dynamic registries. Circul, Cardiovasc Interven. 2009;2(1):6-13.
    1. Neumann F-J, Sousa-Uva M, Ahlsson A, et al. 2018 ESC/EACTS guidelines on myocardial revascularization. Eur Heart J. 2019;40(2):87-165.
    1. Doenst T, Bargenda S, Kirov H, et al. Cardiac surgery 2018 reviewed. Clin Res Cardiol. 2019;108:974-989.
    1. Al-Moghairi AM, Al-Amri HS. Management of retained intervention guide-wire: a literature review. Curr Cardiol Rev. 2013;9(3):260-266.

LinkOut - more resources