. 2020 Aug:129:104540.
doi: 10.1016/j.jcv.2020.104540. Epub 2020 Jul 6.

Quantification of SARS-CoV-2 antibodies with eight commercially available immunoassays

Affiliations

Quantification of SARS-CoV-2 antibodies with eight commercially available immunoassays

Lisa Weidner et al. J Clin Virol. 2020 Aug.

Abstract

Since the emergence of SARS-CoV-2 numerous antibody assays have become available, demonstrating different performance characteristics. This study focused on a quantitative correlation between different commercial assays and a neutralization test (NT). Comparative data is needed as a basis for the production of convalescent plasma and potential interpretations COVID-19 immunity. Sera of 100 SARS-CoV-2 convalescent plasma donors were collected and SARS-CoV-2 antibodies were characterized using three different IgG-ELISAs (EUROIMMUN IgG and NCP-IgG ELISA, Wantai ELISA), two CLIA (Elecsys, LIAISON) and two lateral flow tests (MEDsan IgM/IgG-Rapid-Test, Wantai Rapid Test) and subsequently correlated to neutralization titers. The Wantai ELISA and the Elecsys provide the highest sensitivities in this sample (98 and 95 percent respectively). Titers with the best overall quantitative correlation to the NT titer were obtained with the Euroimmun IgG ELISA assay (Rho=0.759) and the Wantai ELISA assay (Rho=0.729). An infection without fever and negative or weakly positive reactions in the Wantai Rapid test were negative predictive factors for NT titers >1:200 (negative predictive value of 92 % and 92 % respectively, combination of both 100 %). The Wantai ELISA titer could be a suitable substitute for NT. An adequate pooling strategy of plasma units additionally could compensate deviations of individual antibody titers.

Keywords: COVID-19 convalescent plasma; Correlation; Immunoassay; SARS-CoV-2 antibody quantification; Virus neutralization test.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest MRF and TRK are employees of Baxter AG, a Takeda company and have Takeda stock interest. All other authors declare no conflict of interests.

Figures

Fig. 1
Fig. 1
Picture card for Wantai Rapid Test rating.
Fig. 2
Fig. 2
Dotblots of quantitative results of Euroimmun IgG and NCP ELISA titer, Wantai ELISA titer and LIAISON against NT titer.
Fig. 3
Fig. 3
Boxplot Wantai Rapid Test and NT titer.

References

    1. Zhu N., Zhang D., Wang W., et al. A novel coronavirus from patients with pneumonia in China, 2019. N. Engl. J. Med. 2020;382(8):727–733. doi: 10.1056/NEJMoa2001017. - DOI - PMC - PubMed
    1. 2020. Foundation for Innovative New Diagnostics. SARS-COV-2 Diagnostic Pipeline.www.finddx.org/covid-19/pipeline/?section=immunoassays#diag_tab Accessed June 13.
    1. Beavis K.G., Matushek S.M., Abeleda A.P.F., et al. Evaluation of the EUROIMMUN Anti-SARS-CoV-2 ELISA assay for detection of IgA and IgG antibodies. J. Clin. Virol. 2020;129(January) doi: 10.1016/j.jcv.2020.104468. - DOI - PMC - PubMed
    1. Spicuzza L., Montineri A., Manuele R., et al. Reliability and usefulness of a rapid IgM‐IgG antibody test for the diagnosis of SARS-CoV-2 infection: a preliminary report. J. Infect. 2020;(23 April) doi: 10.1016/j.jinf.2020.04.022. - DOI - PMC - PubMed
    1. Tang M.S., Hock K.G., Logsdon N.M., et al. Clinical performance of two SARS-CoV-2 serologic assays. Clin. Chem. 2020;0:0–8. doi: 10.1017/CBO9781107415324.004. - DOI - PMC - PubMed

MeSH terms