Photoplethysmographic evaluation of generalized tonic-clonic seizures
- PMID: 32652564
- DOI: 10.1111/epi.16590
Photoplethysmographic evaluation of generalized tonic-clonic seizures
Abstract
Objective: Photoplethysmography (PPG) is an optical technique measuring variations of blood perfusion in peripheral tissues. We evaluated alterations in PPG signals in relationship to the occurrence of generalized tonic-clonic seizures (GTCSs) in patients with epilepsy to evaluate the feasibility of seizure detection.
Methods: During electroencephalographic (EEG) long-term monitoring, patients wore portable wristband sensor(s) on their wrists or ankles recording PPG signals. We analyzed PPG signals during three time periods, which were defined with respect to seizures detected on EEG: (1) baseline (>30 minutes prior to seizure), (2) preseizure period, and (3) postseizure period. Furthermore, we selected five random control segments during seizure-free periods. PPG features, including frequency, amplitude, duration, slope, smoothness, and area under the curve, were automatically calculated. We used a linear mixed-effect model to evaluate changes in PPG features between different time periods in an attempt to identify signal changes that detect seizures.
Results: We prospectively enrolled 174 patients from the epilepsy monitoring unit at Boston Children's Hospital. Twenty-five GTCSs were recorded from 13 patients. Data from the first recorded GTCS of each patient were included in the analysis. We observed an increase in PPG frequency during pre- and postseizure periods that was higher than the changes during seizure-free periods (frequency increase: preseizure = 0.22 Hz, postseizure = 0.58 Hz vs changes during seizure-free period = 0.05 Hz). The PPG slope decreased significantly by 56.71 nW/s during preseizure periods compared to seizure-free periods. Additionally, the smoothness increased significantly by 0.22 nW/s during the postseizure period compared to seizure-free periods.
Significance: Monitoring of PPG signals may assist in the detection of GTCSs in patients with epilepsy. PPG may serve as a promising biomarker for future seizure detection systems and may contribute to future seizure prediction systems.
Keywords: GTCS; PPG; autonomic; biosensor; epilepsy; seizure.
© 2020 International League Against Epilepsy.
References
REFERENCES
-
- Murray WB, Foster PA. The peripheral pulse wave: information overlooked. J Clin Monit. 1996;12:365-77.
-
- Zijlmans M, Flanagan D, Gotman J. Heart rate changes and ECG abnormalities during epileptic seizures: prevalence and definition of an objective clinical sign. Epilepsia. 2002;43:847-54.
-
- Ulate-Campos A, Coughlin F, Gainza-Lein M, Fernandez IS, Pearl PL, Loddenkemper T. Automated seizure detection systems and their effectiveness for each type of seizure. Seizure. 2016;40:88-101.
-
- Poh MZ, Loddenkemper T, Reinsberger C, et al. Autonomic changes with seizures correlate with postictal EEG suppression. Neurology. 2012;78:1868-76.
-
- Tamilia E, Formica D, Scaini A, Taffoni F. An automated system for the analysis of newborns' oral-motor behavior. IEEE Trans Neural Syst Rehabil Eng. 2016;24:1294-303.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical