Thyroid cytology smear slides: An untapped resource for ThyroSeq testing

Affiliations
Free article

Thyroid cytology smear slides: An untapped resource for ThyroSeq testing

Marina N Nikiforova et al. Cancer Cytopathol. 2021 Jan.
Free article

Abstract

Background: Molecular testing of thyroid nodules with indeterminate fine-needle aspiration (FNA) cytology is commonly used to guide patient management and is typically performed on freshly collected FNA samples. In this study, the authors evaluated the performance of the ThyroSeq test in cytology smear slides.

Methods: Air-dried Diff-Quik (DQ)-stained and alcohol-fixed Papanicolaou (Pap)-stained smears were used to determine required cellularity and sensitivity of mutation detection and to compare ThyroSeq v3 Genomic Classifier (GC) results obtained in cytology smears and fresh FNA samples from the same nodules.

Results: ThyroSeq testing of 31 cytology smears revealed that 25 smears (81%) were adequate for ThyroSeq analysis, including 14 Pap-stained smears (100%) and 11 DQ-stained smears (65%), whereas 6 DQ-stained smears (35%) failed RNA sequencing. The overall accuracy for detecting molecular alterations was 98%, with 100% concordance for mutations and gene expression alterations, 96% concordance for fusions, and 94% concordance for copy number alterations. Cytology smears were adequate for ThyroSeq analysis when at least 200 to 300 cells were present in 1 to 3 slides. ThyroSeq detected all studied mutations down to 5% allele frequency and BRAF mutations down to 1% allele frequency. Testing of smears yielded a positive ThyroSeq GC result in all nodules originally classified as positive.

Conclusions: Thyroid FNA cytology smear slides with adequate cellularity can be successfully used for ThyroSeq GC testing in approximately 80% of cases, with an even higher success rate in Pap-stained smears. Compared with FNA samples collected into preservative solution, 94% to 100% of different genetic alterations could be accurately detected in smears, validating cytology smears as an alternative for ThyroSeq testing in patients with indeterminate thyroid cytology.

Keywords: ThyroSeq; fine-needle aspiration (FNA); indeterminate fine-needle aspiration; next-generation sequencing; thyroid cytology smear; thyroid nodule.

PubMed Disclaimer

References

    1. Durante C, Grani G, Lamartina L, Filetti S, Mandel SJ, Cooper DS. The diagnosis and management of thyroid nodules: a review. JAMA. 2018;319:914-924.
    1. Haugen BR, Alexander EK, Bible KC, et al. 2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association Guidelines Task Force on Thyroid Nodules and Differentiated Thyroid Cancer. Thyroid. 2016;26:1-133.
    1. Cibas ES, Ali SZ. The 2017 Bethesda System for Reporting Thyroid Cytopathology. Thyroid. 2017;27:1341-1346.
    1. Patel KN, Angell TE, Babiarz J, et al. Performance of a genomic sequencing classifier for the preoperative diagnosis of cytologically indeterminate thyroid nodules. JAMA Surg. 2018;153:817-824.
    1. Nikiforova MN, Mercurio S, Wald AI, et al. Analytical performance of the ThyroSeq v3 genomic classifier for cancer diagnosis in thyroid nodules. Cancer. 2018;124:1682-1690.