Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Nov:143:11-16.
doi: 10.1016/j.wneu.2020.07.116. Epub 2020 Jul 23.

Novel Simulation Model with Pulsatile Flow System for Microvascular Training, Research, and Improving Patient Surgical Outcomes

Affiliations

Novel Simulation Model with Pulsatile Flow System for Microvascular Training, Research, and Improving Patient Surgical Outcomes

Federico Carlos Gallardo et al. World Neurosurg. 2020 Nov.

Abstract

Background: Simulation allows surgical trainees to acquire surgical skills in a safe environment. With the aim of reducing the use of animal experimentation, different alternative nonliving models have been pursued. However, one of the main disadvantages of these nonliving models has been the absence of arterial flow, pulsation, and the ability to integrate both during a procedure on a blood vessel. In the present report, we have introduced a microvascular surgery simulation training model that uses a fiscally responsible and replicable pulsatile flow system.

Methods: We connected 30 human placentas to a pulsatile flow system and used them to simulate aneurysm clipping and vascular anastomosis.

Results: The presence of the pulsatile flow system allowed for the simulation of a hydrodynamic mechanism similar to that found in real life. In the aneurysm simulation, the arterial flow could be evaluated before and after clipping the aneurysm using a Doppler ultrasound system. When practicing anastomosis, the use of the pulsatile flow system allowed us to assess the vascular flow through the anastomosis, with verification using the Doppler ultrasound system. Leaks were manifested as "blood" pulsatile ejections and were more frequent at the beginning of the surgical practice, showing a learning curve.

Conclusions: We have provided a step-by-step guide for the assembly of a replicable and inexpensive pulsatile flow system and its use in placentas for the simulation of, and training in, performing different types of anastomoses and intracranial aneurysms surgery.

Keywords: Anastomosis; Aneurysm; Microsurgery; Neurosurgery; Placenta; Training simulation.