Sepsis from an apheresis platelet contaminated with Acinetobacter calcoaceticus/baumannii complex bacteria and Staphylococcus saprophyticus after pathogen reduction
- PMID: 32738079
- DOI: 10.1111/trf.15951
Sepsis from an apheresis platelet contaminated with Acinetobacter calcoaceticus/baumannii complex bacteria and Staphylococcus saprophyticus after pathogen reduction
Abstract
Background: Strategies to reduce platelet (PLT) bacterial contamination include donor screening, skin disinfection, sample diversion, bacterial culture, pathogen reduction (PR), and day-of-transfusion tests. We report bacterial sepsis following a pathogen-reduced PLT transfusion.
Case report: An adult male with relapsed acute lymphoblastic leukemia was successfully treated for central catheter-associated Staphylococcus aureus bacteremia. A peripherally inserted central catheter (PICC) was placed. Chills, rigors, and flushing developed immediately after PICC-infused pathogen-reduced PLTs, progressing to septic shock requiring intensive care management.
Methods: PICC and peripheral blood (PB), transfused bag saline flushes (TBFs), environmental samples, and the pathogen-reduced untransfused co-component (CC) were cultured. Plasma metagenomic and bacterial isolate whole-genome sequencing; PLT mitochondrial DNA (mtDNA) testing of untransfused CC and TBF; CC testing for amotosalen (S-59)/S-59 photoproducts; isolate PR studies (INTERCEPT); and TBF polymerase chain reaction for recipient Y-chromosome DNA were performed.
Results: PB and PICC cultures grew Acinetobacter calcoaceticus/baumannii complex (ACBC). TBF was gram-positive; mass spectrometry identified ACBC and Staphylococcus saprophyticus (SS). CC Gram stain and cultures were negative. Environmental cultures, some done after decontamination, were ACBC/SS negative. Posttransfusion patient plasma and TBF ACBC sequences were genetically identical. No Y-chromosome signal was detected in TBF. S-59 photoproducts and evidence of mtDNA amplification inhibition were found in the CC. Spiking PR studies showed >5.9-log inactivation for both isolates. Donor skin cultures for Acinetobacter were negative.
Conclusion: CC sterility, PR studies, residual S-59 photoproducts, and mtDNA amplification inhibition suggest successful PR. Unidentified environmental sources and inherent or acquired bag defects may have contributed to postmanufacturing pathogen-reduced PLT contamination.
Keywords: Acinetobacter calcoaceticus/baumannii; Staphylococcus saprophyticus; pathogen reduction; septic transfusion reaction.
© 2020 AABB.
References
REFERENCES
-
- Fridey JL. Standards for blood banks and transfusion services. 22nd ed. Bethesda, MD: AABB, 2003;p. 13.
-
- Carson TH. Standards for blood banks and transfusion services. 27th ed. Bethesda, MD: AABB, 2011;p. 11.
-
- US Food and Drug Administration. Bacterial Risk Control Strategies for Blood Collection Establishments and Transfusion Services to Enhance the Safety and Availability of Platelets for Transfusion. Silver Spring, MD: US Department of Health and Human Services, Food and Drug Administration; 2019. [accessed 2020 Oct 7]. https://www.fda.gov/regulatory-information/search-fda-guidance-documents....
-
- Benjamin RJ, Braschler T, Weingand T, Corash LM. Hemovigilance monitoring of platelet septic reactions with effective bacterial protection systems. Transfusion. 2017;57:2946-2957.
-
- McDonald C, Allen J, Brailsford S, et al. Bacterial screening of platelet components by National Health Service Blood and Transplant, an effective risk reduction measure. Transfusion. 2017;57:1122-1131.