Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Oct 13;222(10):1612-1619.
doi: 10.1093/infdis/jiaa487.

Prospective Study Comparing Deep Throat Saliva With Other Respiratory Tract Specimens in the Diagnosis of Novel Coronavirus Disease 2019

Affiliations

Prospective Study Comparing Deep Throat Saliva With Other Respiratory Tract Specimens in the Diagnosis of Novel Coronavirus Disease 2019

Christopher K C Lai et al. J Infect Dis. .

Abstract

Background: Self-collected specimens have been advocated to avoid infectious exposure to healthcare workers. Self-induced sputum in those with a productive cough and saliva in those without a productive cough have been proposed, but sensitivity remains uncertain.

Methods: We performed a prospective study in 2 regional hospitals in Hong Kong.

Results: We prospectively examined 563 serial samples collected during the virus shedding periods of 50 patients: 150 deep throat saliva (DTS), 309 pooled-nasopharyngeal (NP) and throat swabs, and 104 sputum. Deep throat saliva had the lowest overall reverse-transcriptase polymerase chain reaction (RT-PCR)-positive rate (68.7% vs 89.4% [sputum] and 80.9% [pooled NP and throat swabs]) and the lowest viral ribonucleic acid (RNA) concentration (mean log copy/mL 3.54 vs 5.03 [sputum] and 4.63 [pooled NP and throat swabs]). Analyses with respect to time from symptom onset and severity also revealed similar results. Virus yields of DTS correlated with that of sputum (Pearson correlation index 0.76; 95% confidence interval, 0.62-0.86). We estimated that the overall false-negative rate of DTS could be as high as 31.3% and increased 2.7 times among patients without sputum.

Conclusions: Deep throat saliva produced the lowest viral RNA concentration and RT-PCR-positive rate compared with conventional respiratory specimens in all phases of illness. Self-collected sputum should be the choice for patients with sputum.

Keywords: COVID-19; SARS-CoV-2; coronavirus; diagnosis; saliva.

PubMed Disclaimer

Publication types

MeSH terms