Comparative Study
. 2021 Feb 1;132(2):524-535.
doi: 10.1213/ANE.0000000000005031.

Macintosh Videolaryngoscope for Intubation in the Operating Room: A Comparative Quality Improvement Project

Affiliations
Free article
Comparative Study

Macintosh Videolaryngoscope for Intubation in the Operating Room: A Comparative Quality Improvement Project

Audrey De Jong et al. Anesth Analg. .
Free article

Abstract

Background: "Macintosh"-videolaryngoscopes (VLs) are VLs that allow both direct and indirect laryngoscopy for intubation. We describe the decision-making and implementation-processes that our hospital used regarding the choice of device. We compared the performances of 4 Macintosh-VLs both in direct and indirect laryngoscopy.

Methods: A quality-improvement-project for airway management aiming at implementing Macintosh-VL for all intubation procedures performed in the operating room, involving 4 Macintosh-VLs (McGrath-Mac, C-MAC-S, C-MAC-S-Pocket-Monitor [PM], and APA). Three consecutive steps were described: (1) direct laryngoscopy with Macintosh-VL, (2) indirect laryngoscopy with Macintosh-VL (intubation attempt with Macintosh-style blade in case of Cormack I or II), (3) intubation attempt with hyperangulated blade in case of Cormack III/IV or failure of Macintosh-style blade. The main end point was the need to move to step III and use a hyperangulated blade. A mixed-effects multivariable logistic regression analysis was performed to compare devices on the main end point while considering site as a random effect. Comparison of means was performed using analysis of variance and Tukey's test for multiple comparisons (number of laryngoscopy attempts, numeric rate scale [NRS] difficulty of intubation and NRS user-friendliness). Comparison of percentages was performed using a χ2 test for the need to move to step III and a Kruskal-Wallis test for the quality of image (bad, passable, good, very good, excellent). A P value ≤.008 was considered statistically significant.

Results: From May to September 2017, 589 patients were included. Using the McGrath-Mac (22/180 [12%]) was associated with less use of hyperangulated blade than using the C-MAC-S (39/132 [30%], odds ratio [OR] [99.2% confidence interval {CI}] 0.34 [0.16-0.77], P = .0005), the APA (35/138 [25%], OR [99.2% CI] 0.42 [0.19-0.93]; P = .004), but not the C-MAC-S-PM (29/139 [21%], OR [99.2% CI] 0.53 [0.23-1.2]; P = .04).Overall, the number of intubation attempts was significantly lower using the McGrath Mac than the C-MAC-S or the C-MAC-S-PMVLs. Subjective appreciation of intubation difficulty and user-friendliness of the devices showed respectively lower and higher NRS scores for the McGrath-Mac compared to the other devices, whereas subjective assessment of image quality showed higher quality for the C-MAC-S and C-MAC-S-PM compared to the APA or McGrath-Mac.

Conclusions: Among 4 single-use Macintosh-VLs, glottic visualization in direct and indirect laryngoscopy with the Macintosh-style blade was significantly improved with the McGrath-Mac compared to other Macintosh-VLs, leading to a less frequent need to resort to the hyperangulated blade and reduced overall number of intubation attempts.

PubMed Disclaimer

Conflict of interest statement

Conflicts of Interest: See Disclosures at the end of the article.

References

    1. De Jong A, Molinari N, Pouzeratte Y, et al. Difficult intubation in obese patients: incidence, risk factors, and complications in the operating theatre and in intensive care units. Br J Anaesth. 2015;114:297–306.
    1. Cook TM, Kelly FE. A national survey of videolaryngoscopy in the United Kingdom. Br J Anaesth. 2017;118:593–600.
    1. Holmes MG, Dagal A, Feinstein BA, Joffe AM. Airway management practice in adults with an unstable cervical spine: the Harborview Medical Center experience. Anesth Analg. 2018;127:450–454.
    1. Pieters BM, Theunissen M, van Zundert AA. Macintosh blade videolaryngoscopy combined with rigid Bonfils intubation endoscope offers a suitable alternative for patients with difficult airways. Anesth Analg. 2018;126:988–994.
    1. Frerk C, Mitchell VS, McNarry AF, et al.; Difficult Airway Society intubation guidelines working group. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827–848.

Publication types