Analysis of thallium-201 myocardial SPECT images using fuzzy set theory
- PMID: 3275110
- DOI: 10.1007/BF03164947
Analysis of thallium-201 myocardial SPECT images using fuzzy set theory
Abstract
Using the fuzzy set theory, a method was developed for analyzing the extent and severity of ischemia by comparing the exercise and delayed SPECT images with Thallium-201. For each short axial image (slice) for exercise and delayed study, a defect probability matrix (DPM) is created so that it shows the severity of ischemia of myocardium in that slice. Each slice is divided into 8 equi-angle sectors, and the left ventricle (LV) also is divided into 8 equi-angle vertical sectors from apex to base. Using DPMs, the defect probability is calculated for each slice, sectors of each slice and vertical sectors of the LV. The results are displayed on a CRT by means of images, curves and histograms. They show what percentage of the area of each slice and that of the lateral, anterior, septum and inferior portions have how much defect. They provide comprehensive and easily understood information about the condition of the LV in exercise and delayed stages. Persistent and transient ischemia can be diagnosed by visual comparison of patients' curves and histograms with their corresponding normal limits.
Similar articles
-
[Development of a new quantitative analysis for thallium myocardial SPECT images--quantitative STEREO-VIEW method and evaluation of its clinical usefulness].Kaku Igaku. 1989 Jul;26(7):845-54. Kaku Igaku. 1989. PMID: 2810903 Japanese.
-
Comparison of defect size between thallium-201 and technetium-99m tetrofosmin myocardial single-photon emission computed tomography in patients with single-vessel coronary artery disease.Am J Cardiol. 1996 Feb 15;77(5):350-4. doi: 10.1016/s0002-9149(97)89362-9. Am J Cardiol. 1996. PMID: 8602561
-
[Three-dimensional display and its quantification of exercise stress myocardial tomography using thallium-201].J Cardiol. 1992;22(2-3):307-18. J Cardiol. 1992. PMID: 1339789 Japanese.
-
Concordance and discordance between stress-redistribution-reinjection and rest-redistribution thallium imaging for assessing viable myocardium. Comparison with metabolic activity by positron emission tomography.Circulation. 1993 Sep;88(3):941-52. doi: 10.1161/01.cir.88.3.941. Circulation. 1993. PMID: 8353921
-
Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique.J Am Coll Cardiol. 1989 Dec;14(7):1689-99. doi: 10.1016/0735-1097(89)90017-x. J Am Coll Cardiol. 1989. PMID: 2584558
Cited by
-
[Segmentation method of myocardial perfusion bull-eye for the degree of loss of cardiac ischemia].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021 Dec 25;38(6):1072-1080. doi: 10.7507/1001-5515.202102019. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021. PMID: 34970889 Free PMC article. Chinese.
References
MeSH terms
Substances
LinkOut - more resources
Research Materials
Miscellaneous