. 2021 Jul;13(7):605-608.
doi: 10.1136/neurintsurg-2020-016459. Epub 2020 Aug 4.

Vessel diameter and catheter-to-vessel ratio affect the success rate of clot aspiration

Affiliations

Vessel diameter and catheter-to-vessel ratio affect the success rate of clot aspiration

Anna Andriana Kyselyova et al. J Neurointerv Surg. 2021 Jul.

Abstract

Background: A direct aspiration first pass technique (ADAPT) is an efficient, safe, cost-effective, and fast thrombectomy technique.

Objective: To evaluate anatomical and clot characteristics associated with success of the aspiration component as part of ADAPT.

Methods: 106 cases of acute carotid-T, basilar, and middle cerebral artery occlusion undergoing endovascular treatment with ADAPT were retrospectively assessed for successful catheter-clot contact and successful primary aspiration, defined as a Thrombolysis in Cerebral Infarction score ≥2b after primary aspiration with 5F or 6F aspiration catheters. Patient age, National Institutes of Health Stroke Scale (NIHSS) score, time from symptom onset to groin puncture, time from groin puncture to revascularization, aortic arch type, access vessel tortuosity, vessel diameter at the proximal end of the thrombus, catheter-to-vessel ratio (CVR), clot density, length, and perviousness were determined.

Results: Successful clot contact with the aspiration catheter was achieved in 76 cases (72%); these patients were younger (67.7±15.2 vs 73.7±11.4 years; p=0.05) and had less tortuous access vessels (1 vs 2 reverse curves; p=0.004) than those in whom clot contact failed. Successful primary aspiration occurred in 36 of these cases (47%) and was associated with significantly smaller vessel diameter at the proximal thrombus end (2.5±0.7 mm vs 3.1±1.3 mm; p=0.01) and higher CVR (CVR outer diameter: 0.85±0.2 vs 0.68±0.2; p=0.01 and CVR inner diameter: 0.72±0.2 vs 0.58±0.2; p<0.001). No significant differences were seen in aortic arch type, radiographic clot features, and NIHSS score.

Conclusion: With ADAPT, patient age and vessel tortuosity affect the ability to deliver the aspiration catheter and achieve clot contact, whereas vessel diameter and CVR at the aspiration site seem to affect the effectiveness of clot aspiration. Strategies aimed at improving catheter deliverability and increasing CVR may increase the efficacy of ADAPT.

Keywords: intervention; stroke; technique; thrombectomy.

PubMed Disclaimer

Conflict of interest statement

Competing interests: JHB: personal fees as consultant for Microvention, Stryker, Cerenovus, Acandis and Medtronic outside the submitted work. JF: personal fees from Consultant for Microvention, Stryker, Cerenovus, Acandis, Penumbra and Medtronic outside the submitted work. He is a member of the executive board of the scientific societies DGNR and ESMINT.