Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Feb;42(4):374-380.
doi: 10.1002/elps.202000180. Epub 2020 Aug 19.

Improved CE(SDS)-CZE-MS method utilizing an 8-port nanoliter valve

Affiliations

Improved CE(SDS)-CZE-MS method utilizing an 8-port nanoliter valve

Jennifer Römer et al. Electrophoresis. 2021 Feb.

Abstract

Capillary sieving electrophoresis utilizing SDS (CE(SDS)) is one of the most applied methods for the analysis of antibody (mAb) size heterogeneity in the biopharmaceutical industry. Inadequate peak identification of observed protein fragments is still a major issue. In a recent publication, we introduced an electrophoretic 2D system, enabling online mass spectrometric detection of generic CE(SDS) separated peaks and identification of several mAb fragments. However, an improvement regarding system stability and handling of the approach was desired. Here, we introduce a novel 8-port valve in conjunction with an optimized decomplexation strategy. The valve contains four sample loops with increased distances between the separation dimensions. Thus, successively coinjection of solvent and cationic surfactant without any additional detector in the second dimension is enabled, simplifying the decomplexation strategy. Removal efficiency was optimized by testing different volumes of solvents as presample and cationic surfactant as postsample zone. 2D measurements of the light and heavy chain of the reduced NIST mAb with the 8-port valve and the optimized decomplexation strategy demonstrates the increased robustness of the system. The presented novel set-up is a step toward routine application of CE(SDS)-CZE-MS for impurity characterization of proteins in the biopharmaceutical field.

Keywords: CE(SDS); Capillary electrophoresis; Mass spectrometry; Monoclonal antibody; Two-dimensional.

PubMed Disclaimer

References

5 References

    1. Sänger-van de Griend, C. E., Electrophoresis 2019, 40, 2361-2374.
    1. Rundlett, K. L., Armstrong, D. W., Anal. Chem. 1996, 68, 3493-3497.
    1. Schlecht, J., Jooß, K., Neusüß, C., Anal. Bioanal. Chem. 2018, 410, 6353-6359.
    1. Kler, P. A., Sydes, D., Huhn, C., Anal. Bioanal. Chem. 2015, 407, 119-138.
    1. Kohl, F. J., Montealegre, C., Neusüß, C., Electrophoresis 2016, 37, 954-958.

Publication types

MeSH terms

Substances

LinkOut - more resources