Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Dec:80:105137.
doi: 10.1016/j.clinbiomech.2020.105137. Epub 2020 Jul 31.

Reduced force entropy in subacromial pain syndrome: A cross-sectional analysis

Affiliations
Free article

Reduced force entropy in subacromial pain syndrome: A cross-sectional analysis

Celeste L Overbeek et al. Clin Biomech (Bristol). 2020 Dec.
Free article

Abstract

Background: Generating a force at the hand requires moments about multiple joints by a theoretically infinite number of arm and shoulder muscle force combinations. This allows for learning and adaptation and can possibly be captured using the complexity (entropy) of an isometrically generated force curve. Patients with Subacromial Pain Syndrome have difficulty to explore alternative, pain-avoiding, motor strategies and we questioned whether loss of motor complexity may contribute to this. We assessed whether patients with Subacromial Pain Syndrome have reduced entropy of an isometrically generated abduction and adduction force curve.

Methods: Forty patients and thirty controls generated submaximal isometric ab- and adduction force at the wrist. The force curve was characterized by the magnitude of force variability [standard deviation and coefficient of variation], and the entropy (complexity) of force variability [approximate entropy].

Findings: Patients showed reduced entropy both during the abduction (-0.16, confidence interval: [-0.33; -0.00], p: 0.048) and adduction task (-0.20, confidence interval: [-0.37; -0.03], p: 0.024) and reduced force variability during abduction (standard deviation: -0.006, confidence interval: [-0.011; -0.001], p: 0.013 and coefficient of variation: -0.51, confidence interval: [-0.93; -0. 10], p: 0.016).

Interpretations: Isometric force curves of patients with Subacromial Pain Syndrome show reduced complexity compared to asymptomatic controls, which may indicate more narrow and stereotype use of motor options. In future studies, it should be investigated whether the finding of reduced force (motor) entropy indicates functional decline, contributing to decreased ability to acquire and optimize motor strategies in Subacromial Pain Syndrome.

Level of evidence: Level II prognostic study.

Keywords: Approximate entropy; Force steadiness; Motor control; Physiotherapy; Subacromial pain syndrome.

PubMed Disclaimer

Publication types