Computer-navigated versus conventional total knee arthroplasty: A randomized controlled trial protocol in China
- PMID: 32769888
- PMCID: PMC7593008
- DOI: 10.1097/MD.0000000000021508
Computer-navigated versus conventional total knee arthroplasty: A randomized controlled trial protocol in China
Expression of concern in
-
Expression of Concern: Study Protocols.Medicine (Baltimore). 2025 Nov 7;104(45):e46330. doi: 10.1097/MD.0000000000046330. Medicine (Baltimore). 2025. PMID: 41204616 Free PMC article. No abstract available.
Abstract
Background: The literature lacks studies that confirm whether the improved radiographic alignment that can be achieved with computer-navigated total knee arthroplasty (TKA) improves patients' activities of daily living or the durability of total knee prostheses. Thus, in this protocol, we designed a randomized controlled trial to compare implant alignment, functional scores, and survival of the implant using computer-assisted surgery versus a conventional surgical technique.
Methods: This prospective, blinded randomized controlled trial was conducted at our single hospital. This study was approved by the ethics committee of Jiaxing Second Hospital. The patient inclusion criteria were age 20 to 80 years' old, a body mass index of ≤35 kg/m, and consented for primary knee arthroplasty performed through a medial parapatellar approach by the senior author. We randomized consented study participants on a 1:1 ratio to 1 of 2 study groups using a computer-generated list of random numbers in varying block sizes. The primary outcome in this study was the Knee Injury and Osteoarthritis Outcome Score. Secondary outcomes were the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index, complications, and range of motion together with alignment and rotational positioning of the implant. Statistical significance was defined as a P value of ≤0.05.
Conclusions: Authors hypothesized that computer-assisted surgery in primary TKA improves implant alignment, functional scores, and survival of the implant compared to the conventional technique.
Conflict of interest statement
The authors report no conflicts of interest.
Figures
References
-
- Li S, Luo X, Wang P, et al. Clinical outcomes of gap balancing vs measured resection in total knee arthroplasty: a systematic review and meta-analysis involving 2259 subjects. J Arthroplasty 2018;33:2684–93. - PubMed
-
- Kim YH, Park JW, Kim JS. Computer-navigated versus conventional total knee arthroplasty a prospective randomized trial. J Bone Joint Surg Am 2012;94:2017–24. - PubMed
-
- Matziolis G, Krocker D, Weiss U, et al. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 2007;89:236–43. - PubMed
-
- Bäthis H, Perlick L, Tingart M, et al. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 2004;86:682–7. - PubMed
-
- Ensini A, Catani F, Leardini A, et al. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 2007;457:156–62. - PubMed